Tandberg Data T40 manual Configuring Network Settings

Page 43

Welcome - Welcomes you to the Setup Wizard.

Configuring Network Settings (FPI) - Allows you to enter your network settings for remote access.

Choosing the Interface: Local or Remote (FPI) - Allows you to choose to continue on the front panel or on the remote management interface. If you choose Local, the wizard proceeds on the front panel. If you choose Remote, the FPI presents a Refresh button that needs to be selected until the Network Setting appears. Exit the front panel, log in to the remote management interface using the Network Setting, and select Setup Wizard to resume configuring your library.

Applying a License Key (FPI and RMI) - Allows you to enter a numeric code (License Key) for capacity on demand.

Configuring I/E Slots (FPI and RMI) - Allows you to configure the number of Import/Export (I/E) slots.

Configuring Cleaning Slots (FPI and RMI) - Allows you to configure the number of dedicated cleaning slots to be used through the host application.

Configuring Partitions (FPI and RMI) - Allows you to select the number of partitions and the drives and magazines assigned to each partition.

Setting Tape Drive ID (FPI and RMI) Allows you to configure the SCSI ID of the SCSI drives if your library includes SCSI drives. If your library includes fiber channel drives the FC node name and port name appear.

Modifying Control Path (FPI and RMI) - Allows you to configure which drive shall be the control path in each of the partitions.

Modifying Library Inquiry String (FPI and RMI) - Allows you to configure the inquiry string for the library.

Configuring Autoclean (FPI and RMI) - Allows you to enable/disable automatic drive cleaning.

Configuring Password (FPI and RMI) - Allows you to set password on the FPI.

Configuring Menu Timeout (FPI and RMI) - Allows you to configure the timeout delay on the front panel and RMI menus.

Setting Date and Time (FPI and RMI) - Allows you to set the date and time on your library (set the real time clock).

Configuring Barcode Scan (FPI and RMI) - Allows you to enable/disable the barcode reader.

Configuring Audible Alarm (FPI and RMI) - Allows you to enable/disable the audible alarm.

Confirm Settings (FPI and RMI) - Allows you to confirm your library settings.

Note

Configure the date and time of the library from the Setup menu immediately

following initial configuration of the library using the Setup Wizard.

 

The front panel displays the Setup Wizard the first time you power on. After that, you can log in as Administrator to access the Setup Wizard. The paths to open the appropriate screen are:

From the RMI, select Setup > Setup Wizard

From the FPI, select Setup > Setup Wizard

Configuring Network Settings

The Network configuration screen provides information on the network settings that are configurable from the front panel. The network settings include:

Dynamic or static IP address

StorageLibrary Installation and User Guide

35

Image 43
Contents Installation and User Guide Copyright 2006 Tandberg Data ASA Table of Contents Information about the Operator Interfaces Updating Firmware Approved Drive Types Figures Tables Product Model Number Explanation of Symbols and NotesAbout This Guide Waste Electrical and Electronic Equipment DirectiveGetting More Information or Help Other Documents You Might NeedProduct Description Product OverviewTape Drive Support Magazines Data Transfer RatesFront Panel Control Buttons LED IndicatorsStandby Switch Rear PanelOperator Interfaces Library FeaturesADI Bridging and LUN Simple Network Management Protocol Snmp PartitionsControl Path StationBrowser Requirements Finding a Location for the StorageLibrary Unpacking the StorageLibraryUnpack Page Remove the Transport Locking Screws Installing the LibraryMounting the StorageLibrary in a Rack Rack mounting Kit with Rack mount Ears Right figure Mounting the Rack mount EarsInstalling the Left Rail Assembly Installing the Rails in a RackInstalling the Right Rail Assembly Step Mounting the StorageLibrary to the RackConnecting Library Cables Scsi Installing the LibraryGuidelines for Connecting the Scsi Cables Connecting Library Cables Fibre ChannelConnecting the Cables System Power-on Labeling Cartridges for the Barcode Reader Page Front Panel Interface FPI Information about the Operator InterfacesScroll Function Menu Trees Remote Management InterfacePage Reports Library Operations Assign Media Import Media Setup Setup WizardTools Prepare to Ship Restore Default NetworkLicense Key RAS Tickets Statistics Operations Export Media Setup SlotsDrive FW Upgrade System Test Cycle test Reset Web Password Reports NetworkPage Import Media Network Operations Assign Media Setup Setup WizardTools Maintenance DiagnosticsTools License Key Notification Web Password Reports NetworkHome Screen RAS Tickets StatisticsRMI Home Screen Operator PrivilegesWord Symbol on FPI DescriptionSymbol Description Words Commonly Used on the FPI and RMIMap Menu Status Page About the Setup Wizard Configuring the LibraryUsing the Default Administrative User Account Administrator Setup Wizard Tasks Using the Setup WizardConfiguring Network Settings Applying a License Key Remote AccessConfiguring Cleaning Slots Configuring I/E SlotsFrom the FPI, select Setup Activate License From the RMI, select Setup Partition/Drive Configuring PartitionsCreating Partitions Changing Partition Modes Reconfigure PartitionsModifying the Control Path Setting Drive IDConfiguring FPI Password Configuring AutocleanConfiguring Barcode Scan Configuring RMI PasswordConfiguring Menu Timeout Setting Date and TimeConfiguring Snmp Configuring Audible AlarmConfiguring E-mail Notification Page Importing Cartridges Running the LibraryLogging Logging OutImporting Cartridges via I/E Slot Import Cartridges via Bulk Loading of Magazines Exporting CartridgesLoading to Tape Drives Unloading from Tape DrivesExporting Cleaning Media Cleaning Tape DrivesImporting Cleaning Media Cleaning Media HandlingTaking a Library Online Manual CleanTaking the Library Online/Offline Magazine HandlingInserting Cartridges into the Magazine Removing the Magazine from the UnitRemoving Cartridges from the Magazine Manual/Emergency Release of Magazines Inserting a Magazine into the UnitStandby Functionality Viewing Partitions/Drive Settings Viewing Library SettingsGetting Status and Information Viewing Statistics Viewing Network SettingsViewing Log Page Required tools None Power Supply UnitRemoving and Replacing a Power Supply Adding, Removing and ReplacingAdding a Tape Drive Tape Drive UnitRequired tools Screwdriver Removing and Replacing a Tape Drive Permanently Removing a Tape DrivePage Updating Library Firmware Updating FirmwareUpdating Drive Firmware From the RMI, select Tools Drive SettingsFrom the FPI, select Tools Drive Settings Page Handling Cartridges Properly Working With Cartridges and BarcodesWrite-Protecting Cartridges Installing Barcode LabelsBarcode Requirements About RAS Tickets TroubleshootingViewing RAS Tickets Display Message Description Ticket Suggested Action Closing RAS TicketsSupported RAS Tickets Supported RAS Tickets Parameters and PriorityDisplay Message Interpreting LEDs Item name Maintenance MenusDiagnostics Menu Verifying HardwareSoftware Checking Troubleshooting MatrixVerifying Recent Changes Problem Power Solution Problem Cartridge Movement Problem Scsi problems Problem MediaProblem Cleaning Problem Library PerformanceProblem LED Error Messages Problem Write or Read IssuesProblem Solution Errors Displayed on Front Panel Problem Forgot Password Problem Remote ManagementReinserting the Transport Locking Screws Shipping or Transporting StorageLibraryTransport Locking Screws Marked with Red Plastic Tab Packing the StorageLibraryT40 Library 4U control module SpecificationsWeight Library DimensionsLibrary Component Weights DimensionsClimatic Specifications Power RequirementsPage Europe Safety and Regulatory InformationSafety Approvals EMC ApprovalsAustralia/New Zealand Conformity DeclarationsJapan CanadaApproved Drive Types