Configuring RMI Password

Logging in to the RMI, there is always a level of security. It is not possible to access the library remotely without entering a password. Use the default administrator account if you want to log in as administrator and the default operator account if you want to log in as operator. The default administrator user name is Administrator and the default password field is blank. The default operator user name is Operator and the default password field is blank.

The remote Administrator has access to all features in the library, and the remote Operator has access to the same features as the local Operator. The remote Administrator is the only one to set the remote passwords for both the Administrator and Operator. All remote Operators log in using the same password. All remote Administrators log in using the same password.

Note that when setting the remote password, the password is transmitted in plain text over the network. On subsequent use however, password encryption is used.

The path to open the appropriate screen is:

From the RMI, select Setup > Remote Password

Configuring Menu Timeout

The Menu Timeout feature allows you to configure the timeout delay on the front panel and remote management interface. If there has been no activity on the front panel interface or remote management interface for a certain time, the FPI and RMI screens return to the home screens. The menu timeout is user settable from 1 to 9 minutes. The default value is 1 minute.

The menu timeout is configured with the Setup Wizard. After the initial setup of your library you can later access the Menu Timeout configuration screens directly:

From the RMI, select Setup > Library

From the FPI, select Setup > Library

Setting Date and Time

The library is equipped with a battery backed up real time clock. The time is set up in the factory but needs to be set up to the local time by the user. At a minimum, it is recommended that the librarys date and time be set during initial configuration. The settings are used to log the date and time events took place. The library date and time settings can be modified any time.

The time is set to a 24 hour clock. For example, four oclock in the afternoon is entered as 16:00.

The Date & Time is configured with the Setup Wizard. After the initial setup of your library you can later access the Date & Time configuration screens directly:

From the RMI, select Setup > Library

From the FPI, select Setup > Library

Configuring Barcode Scan

This feature allows the operator to enable or disable the barcode scanner from the front panel interface or the remote management interface. The default for the library is barcode scanner enabled. If disabled, the library is forced to initialize slots by touch.

42

Configuring the Library

Image 50
Contents Installation and User Guide Copyright 2006 Tandberg Data ASA Table of Contents Information about the Operator Interfaces Updating Firmware Approved Drive Types Figures Tables Waste Electrical and Electronic Equipment Directive Explanation of Symbols and NotesAbout This Guide Product Model NumberOther Documents You Might Need Getting More Information or HelpTape Drive Support Product OverviewProduct Description Front Panel Data Transfer RatesMagazines Rear Panel LED IndicatorsStandby Switch Control ButtonsADI Bridging and LUN Library FeaturesOperator Interfaces Station PartitionsControl Path Simple Network Management Protocol SnmpBrowser Requirements Unpack Unpacking the StorageLibraryFinding a Location for the StorageLibrary Page Installing the Library Remove the Transport Locking ScrewsMounting the StorageLibrary in a Rack Mounting the Rack mount Ears Rack mounting Kit with Rack mount Ears Right figureInstalling the Right Rail Assembly Installing the Rails in a RackInstalling the Left Rail Assembly Mounting the StorageLibrary to the Rack StepInstalling the Library Connecting Library Cables ScsiConnecting the Cables Connecting Library Cables Fibre ChannelGuidelines for Connecting the Scsi Cables System Power-on Labeling Cartridges for the Barcode Reader Page Scroll Function Information about the Operator InterfacesFront Panel Interface FPI Remote Management Interface Menu TreesPage Network Operations Assign Media Import Media Setup Setup WizardTools Prepare to Ship Restore Default Reports LibraryReports Network Operations Export Media Setup SlotsDrive FW Upgrade System Test Cycle test Reset Web Password License Key RAS Tickets StatisticsPage Diagnostics Operations Assign Media Setup Setup WizardTools Maintenance Import Media NetworkRAS Tickets Statistics License Key Notification Web Password Reports NetworkHome Screen ToolsOperator Privileges RMI Home ScreenWords Commonly Used on the FPI and RMI Symbol on FPI DescriptionSymbol Description WordMap Menu Status Page Using the Default Administrative User Account Administrator Configuring the LibraryAbout the Setup Wizard Using the Setup Wizard Setup Wizard TasksConfiguring Network Settings Remote Access Applying a License KeyFrom the FPI, select Setup Activate License Configuring I/E SlotsConfiguring Cleaning Slots Creating Partitions Configuring PartitionsFrom the RMI, select Setup Partition/Drive Reconfigure Partitions Changing Partition ModesSetting Drive ID Modifying the Control PathConfiguring Autoclean Configuring FPI PasswordSetting Date and Time Configuring RMI PasswordConfiguring Menu Timeout Configuring Barcode ScanConfiguring E-mail Notification Configuring Audible AlarmConfiguring Snmp Page Logging Out Running the LibraryLogging Importing CartridgesImporting Cartridges via I/E Slot Unloading from Tape Drives Exporting CartridgesLoading to Tape Drives Import Cartridges via Bulk Loading of MagazinesCleaning Media Handling Cleaning Tape DrivesImporting Cleaning Media Exporting Cleaning MediaMagazine Handling Manual CleanTaking the Library Online/Offline Taking a Library OnlineRemoving Cartridges from the Magazine Removing the Magazine from the UnitInserting Cartridges into the Magazine Inserting a Magazine into the Unit Manual/Emergency Release of MagazinesStandby Functionality Getting Status and Information Viewing Library SettingsViewing Partitions/Drive Settings Viewing Network Settings Viewing StatisticsViewing Log Page Adding, Removing and Replacing Power Supply UnitRemoving and Replacing a Power Supply Required tools NoneRequired tools Screwdriver Tape Drive UnitAdding a Tape Drive Permanently Removing a Tape Drive Removing and Replacing a Tape DrivePage Updating Firmware Updating Library FirmwareFrom the RMI, select Tools Drive Settings Updating Drive FirmwareFrom the FPI, select Tools Drive Settings Page Working With Cartridges and Barcodes Handling Cartridges ProperlyBarcode Requirements Installing Barcode LabelsWrite-Protecting Cartridges Viewing RAS Tickets TroubleshootingAbout RAS Tickets Supported RAS Tickets Parameters and Priority Closing RAS TicketsSupported RAS Tickets Display Message Description Ticket Suggested ActionDisplay Message Interpreting LEDs Verifying Hardware Maintenance MenusDiagnostics Menu Item nameVerifying Recent Changes Troubleshooting MatrixSoftware Checking Problem Power Solution Problem Cartridge Movement Problem Media Problem Scsi problemsProblem Library Performance Problem CleaningProblem Solution Errors Displayed on Front Panel Problem Write or Read IssuesProblem LED Error Messages Problem Remote Management Problem Forgot PasswordShipping or Transporting StorageLibrary Reinserting the Transport Locking ScrewsPacking the StorageLibrary Transport Locking Screws Marked with Red Plastic TabSpecifications T40 Library 4U control moduleDimensions Library DimensionsLibrary Component Weights WeightPower Requirements Climatic SpecificationsPage EMC Approvals Safety and Regulatory InformationSafety Approvals EuropeCanada Conformity DeclarationsJapan Australia/New ZealandApproved Drive Types
Related manuals
Manual 5 pages 53.87 Kb

T40 specifications

Tandberg Data T40 represents a significant advancement in data storage technology, offering users a robust and reliable solution for managing and preserving their information. This external tape drive is designed for small to medium-sized businesses that require high-capacity backup and archiving options. The T40 seamlessly combines efficiency with cutting-edge technology, making it a favored choice among IT professionals.

One of the standout features of the Tandberg Data T40 is its native capacity, which supports 1.5TB of storage per cartridge. With data compression, this capacity can effectively double, allowing for up to 3TB of data to be backed up in a single cartridge. This high capacity minimizes the number of tapes needed for extensive data storage, streamlining the backup process.

The T40 utilizes LTO technology, specifically LTO-5, LTO-6, or LTO-7, depending on the model. LTO, or Linear Tape-Open, is known for its high performance and reliability, offering fast data transfer rates. The T40 can achieve transfer speeds of up to 140MB/s, significantly reducing backup windows and enhancing overall productivity. Its backward compatibility ensures that users can access data stored on previous LTO generations, providing additional flexibility and security for businesses transitioning to newer technologies.

Additionally, the T40 features a simple, user-friendly interface that facilitates easy operation and maintenance. Equipped with a built-in LCD display, users can easily monitor the status of the tape drive, eliminating unnecessary guesswork. The drive's design supports extensive connectivity options, including USB 3.0 and SAS interfaces, making it compatible with various systems and infrastructure setups.

The Tandberg Data T40 is also designed with durability in mind. Its robust construction includes features that protect against dust and other environmental factors, ensuring the longevity of the device. Furthermore, its energy-efficient design helps reduce operational costs, making it an economical choice for budget-conscious organizations.

In summary, the Tandberg Data T40 is a powerful external tape drive that combines high capacity, fast performance, and reliability. Its LTO technology, ease of use, and durability make it an invaluable asset for businesses looking to safeguard their critical data while maximizing storage efficiency. Whether for backup or archiving needs, the T40 stands out as a versatile and dependable solution in the data storage landscape.