2 of 5 Data Length
2 of 5 Code is so susceptible to interpreting partial scans as valid reads that the RF Laser uses
LENGTH TO 00 or you will get misreads!
Code 93
Enable Code 93 | 0 |
Disable Code 93 | 1 |
Enable Full ASCII Code 93 | 2 |
Disable Full ASCII Code 93 | 3 |
For more information on Code 93 see Appendix D.
Terminator characters (This applies to the BASE only)
CR (Enter) | 0 |
Tab | 1 |
None | 2 |
Depending on your application, you may wish your RF Laser to transmit bar code data to your computer with an Enter (carriage return), a Tab at the end, or with no extra terminating character at all.
If you need a terminator character other than CR or TAB, you can get it by specifying None here and then selecting your desired terminator character(s) specified in the Postamble (See Page 15).
Beep Options
Decode and Acknowledge | 0 |
Acknowledge Only | 1 |
Preamble
A "Preamble" is a
14