RF Laser Setup (cont.)
| Start Setup |
| End Setup |
*/+/* |
| ||
|
|
| |
|
|
| |
Code 3 of 9 |
| UPC/EAN | |
*/A/* |
| */B/* | |
*0 | Enable Code 39 | * 0 | Enable UPC/EAN |
1 | Disable Code 39 | 1 | Disable UPC/EAN |
*2 | Enable Full ASCII Code 39 | 2 | Enable Supplements |
3 | Disable Full ASCII Code 39 | * 3 | Disable Supplements |
*4 | Enable Accumulate Mode | * 4 | Transmit |
5 | Disable Accumulate Mode | 5 | Don’t transmit |
6 | Transmit Start/Stop characters | * 6 | Transmit |
*7 | Don’t transmit Start/Stop characters | 7 | Don’t transmit |
8 | Enable Mod 43 Check Character | 8 | Transmit |
*9 | Disable Mod 43 Check Character | * 9 | Don’t transmit |
A Transmit Mod 43 Check Character |
| Flag Ch | |
*B Don’t transmit Mod 43 Check | A Transmit | ||
| Character | * B Don’t transmit | |
C Caps Lock ON |
| Check digit | |
*D Caps Lock OFF | * C | ||
|
| D |
* E
F
2 of 5 Code
*/C/*
0Enable I 2 of 5 *1 Disable I 2 of 5
2Enable check digit *3 Disable check digit
4Transmit check digit
*5 Don’t transmit check digit
6Enable 2 of 5 *7 Disable 2 of 5
2 of 5 Length
*/5/*
Scan 2 digit length (default is 06)
RSS-14
*/%/*
* 0 | Disable | 2 | 14 + Identifiers |
1 | Standard 14 digits | 3 | 14 + |
Codabar | MSI/Plessey | ||
*/D/* | */R/* | ||
0 | Enable Codabar | * 0 | Disable MSI |
*1 | Disable Codabar | 1 | Enable MSI 1 Mod 10 check digit |
2 | Enable CLSI Codabar | 2 | Enable MSI 2 Mod 10 check digits |
*3 | Disable CLSI Codabar | 3 | Enable MSI Mod 11/10 check digits |
*4 | Suppress start/stop characters | * 4 | Transmit no check digit |
5 | Enable start/stop characters | 5 | Transmit 1 check digit |
|
| 6 | Transmit 2 check digits |
|
| 7 | Enable Plessey |
|
| 8 | Enable Labelcode 5 |
|
| 9 | Enable Labelcode 4 |
48