Worth Data RF Laser user manual Characters, Set ID Character, Link Test Code

Page 19

Bar Code Data

Postamble

Data Transmitted

123

XYZ

123XYZ

12345678

~3XYZ

12345XYZ

12345678

~9

12345678

12345

~A

12345

123456

~5

1

Bar codes that are shorter than the sum of the Postamble trimming and Preamble trimming will be transmitted without trimming. Selective trimming and min/max bar code data is also supported through Postamble specifications, (See Preamble above for complete details).

Characters

This setup option allows you to output ASCII characters different from the ones scanned.

For example: Suppose you want the RF Laser to output a hex 92 character every time you scan a 1 (hex 31); you want to remap hex 31 to hex 92, (If you're using 8 data bits, output of 80-F8 codes is possible.)

1)Scan the Start Setup Bar Code

2)Scan the Characters Bar Code on the Setup Sheet.

3)Scan 3 1 and 9 2 to output hex 92 when reading a "1".

4)Scan up to 7 other pairs of character reassignments.

5)Scan Set when complete.

6)Scan End Setup to exit setup mode.

Hex values for each character code are shown on the Full ASCII Menu. The equivalent decimal values are also shown for each character.

You can also eliminate characters by reassigning hex codes to FF. For example, to strip all $ (dollar sign) characters from transmission, you would follow the above instructions and scan 2 4 F F in step 3.

Set ID Character

The ID is used to differentiate between multiple RF Lasers attached to the same Base Station.

Multiple scanners on one base station require each scanner to be set to a unique ID of 0,1,2,3.....9. Scan Set ID Character and then scan 0-9for each

scanner, giving each a different ID of 0-9.

Link Test Code

This is a code to test the transmission link between the RF Laser and its Base Station, without transmitting data. You can use this to be sure you are in range and able to hear the base station beeping. No data is transmitted. Do not enter

16

Image 19
Contents Worth Data Inc August Page Table Of Contents Introduction Components of RF Laser Readers InstallationScanner Beeps and LEDs what they mean USB Installation Installing the R/F Reader with a dedicated serial port Menu Installing the R/F Reader between a computer and terminalMod Laser Serial Model Pin-outsF34, DB25 Null Modem Cable F36, DB9 Straight Cable Pin-outsUPC\EAN Laser Scanning Instructions Using The RF Laser Setup Menu Code 3 of 9 Code ChannelUPC/EAN Code 5 Code Disable MSIMSI and Plessey CodabarBeep Options 5 Data LengthPreamble 12345678 PostambleBar Code Data Preamble Data Transmitted 123 XYZ123Set ID Character CharactersLink Test Code Scan Start Setup Scan 2 ResetScan Start Setup Scan Aiming Dot Duration Scan End SetupScan Start Setup Scan 2 of 5 Code Scan Start Setup Scan TerminatorScan Start Setup Scan Code Stop bits Baud rateData bits ParityTest the RF Laser with your computer Page Operational Details Radio ConsiderationsRange Accumulate Mode PC Key Full Ascii Menu Bar Code Function/Control Key SupportFull Ascii Menu Command and Option Keys on Mac USB KeyboardsFunction keys F11 and F12 Windows KeyPoor read rate TroubleshootingAll Models Troubleshooting Reader wont beep when reading bar codesWindows XP USB Trouble ShootingReader doesnt beep when you try to read your bar codes Serial TroubleshootingData characters are garbled or missing Changing Jumpers and Channels Page Recharging the Batteries American National Standards Institute Customer Service Specifications for CodeValue 22 is the Check Character Table C-1. Mod 43 Check character calculation for Code+ 2 + 3 + 33 + 34 + 35 = 108/43 = 2 with a RemainderTable C-2. Full Ascii Table Full Ascii Extension to CodeCode 93 Specifications A12345b Codabar SpecificationsUCC-128/ EAN-128 Code 128 SpecificationsGS1 US Interleaved 2 of 5 Mod 10 check digit calculation Interleaved 2 of 5 Code019873 60 57 =UPC Specifications UPC 2 and 5-character supplemental codes Isbn Specifications+ 9 + 5 + 1 + 8 = 18314589938+ 9 +8 + 4 + 3 + 1 = 33 x 3 =01234500006 123450000601234565 MSI/Plessey Specifications 195/11 = 17 remainder 9434578424,5,6,7,2,3,4,5,6,7 + 12 + 32 + 35 + 30 + 28 + 6 + 12 + 36 =RF Laser Setup RF Laser Setup MenuLink Test Code RSS-14 Code 35 Code 5 LengthSET Clear CodeStart Setup for Base only RF Base Station Setup MenuFull Ascii Menu 056 057 058 059 060 061 062 063 064 065 066 067 +X* *+Y* *+Z* *%P +T* *+U* *+V* *+W%R* *%S* *%T 33, 37, 38, 39, 43 IndexSee Appendix J UPC/EAN