MSI and Plessey
Disable MSI |
| 0 |
Enable MSI with 1 | Mod 10 check digit | 1 |
Enable MSI with 2 | Mod 10 check digits | 2 |
Enable MSI with 1 | Mod 11 and 1 Mod 10 check digit | 3 |
Transmit No Check Digits | 4 | |
Transmit 1 | Check digit | 5 |
Transmit 2 | Check digits | 6 |
Enable Plessey (mutually exclusive with MSI) | 7 | |
Enable LabelCode5 | 8 | |
Enable LabelCode4 | 9 |
For more information about MSI code, see Appendix I.
Codabar
Enable Codabar | 0 |
Disable Codabar | 1 |
Enable CLSI Codabar | 2 |
Disable CLSI Codaber | 3 |
Enable Start/Stop Character Transmission | 4 |
Disable Start/Stop Character Transmission | 5 |
For information about Codabar, see Appendix E.
CLSI format is a form of Codabar often used by libraries.
Enabling Start/Stop character transmission means that the RF Laser will transmit start/stop characters to your computer along with data. If you're varying start/stop characters with different label types, you'll want to enable transmission.
2 of 5 Code
Enable Interleaved 2 of 5 | 0 |
Disable Interleaved 2 of 5 | 1 |
Enable Interleaved 2 of 5 Check Digit | 2 |
Disable Interleaved 2 of 5 Check Digit | 3 |
Enable Check Digit Transmission | 4 |
Disable Check Digit Transmission | 5 |
Enable Standard 2 of 5 | 6 |
Disable Standard 2 of 5 | 7 |
For information about Interleaved and Standard 2 of 5, see Appendix G. Enabling the Check Digit requires the data's units position to match the calculation for the check digit explained in Appendix F. If you've enabled the check digit, enabling Check Digit transmission causes the reader to transmit it to your computer along with the bar code data.
13