Worth Data user manual RF Laser Setup Menu, Link Test Code

Page 51

Appendix J

RF Laser Setup Menu

To change a setting using the RF Laser Setup Menu:

Scan START SETUP to enter setup mode

Scan the parameter you want to change (i.e. Code 3 of 9)

Choose the setting you want to change and scan the corresponding letter or number from the Barpad Table (0-9, A-F)

When all changes have been made, scan END SETUP

For Preamble and Postamble settings, use the FULL ASCII MENU

* indicates default settings

RF Laser Setup

 

Start Setup

End Setup

*/+/*

*/-/*

 

 

 

 

 

 

 

 

 

Channel

Aiming Dot Duration

*/0/*

*/K/*

 

Scan 0-9 to select channel

Scan 2 digits from 00 to 99 (9.9 seconds) to

 

 

set aiming dot duration.

 

 

 

 

 

Preamble

Postamble

*/1/*

*/2/*

 

 

Scan up to 15 characters from the Full

Scan up to 15 characters from the Full ASCII

 

ASCII Menu. Scan SET when completed.

Menu. Scan SET when completed.

 

 

 

 

 

Terminator Character

Characters

 

*/H/*

*.1.*

 

* 0 Enter

Scan up to 8 sets of hex characters to

 

1 None

reassign and delete characters in the bar

 

2 Tab

code output. Scan SET when completed.

Link Test Code

*--*

Test RF Transmission without tramsmitting data.

47

Image 51
Contents Worth Data Inc August Page Table Of Contents Introduction Installation Components of RF Laser ReadersScanner Beeps and LEDs what they mean USB Installation Installing the R/F Reader with a dedicated serial port Menu Installing the R/F Reader between a computer and terminalMod Laser Serial Model Pin-outsF34, DB25 Null Modem Cable F36, DB9 Straight Cable Pin-outsUPC\EAN Laser Scanning Instructions Using The RF Laser Setup Menu Code 3 of 9 Code ChannelUPC/EAN Code 5 Code Disable MSIMSI and Plessey Codabar5 Data Length Beep OptionsPreamble 12345678 PostambleBar Code Data Preamble Data Transmitted 123 XYZ123Characters Set ID CharacterLink Test Code Scan Start Setup Scan 2 ResetScan Start Setup Scan Aiming Dot Duration Scan End SetupScan Start Setup Scan Terminator Scan Start Setup Scan 2 of 5 CodeScan Start Setup Scan Code Stop bits Baud rateData bits ParityTest the RF Laser with your computer Page Radio Considerations Operational DetailsRange Accumulate Mode PC Key Full Ascii Menu Bar Code Function/Control Key SupportFull Ascii Menu Command and Option Keys on Mac USB KeyboardsFunction keys F11 and F12 Windows KeyPoor read rate TroubleshootingAll Models Troubleshooting Reader wont beep when reading bar codesWindows XP USB Trouble ShootingReader doesnt beep when you try to read your bar codes Serial TroubleshootingData characters are garbled or missing Changing Jumpers and Channels Page Recharging the Batteries American National Standards Institute Customer Service Specifications for CodeValue 22 is the Check Character Table C-1. Mod 43 Check character calculation for Code+ 2 + 3 + 33 + 34 + 35 = 108/43 = 2 with a RemainderTable C-2. Full Ascii Table Full Ascii Extension to CodeCode 93 Specifications A12345b Codabar SpecificationsUCC-128/ EAN-128 Code 128 SpecificationsGS1 US Interleaved 2 of 5 Mod 10 check digit calculation Interleaved 2 of 5 Code019873 60 57 =UPC Specifications UPC 2 and 5-character supplemental codes Isbn Specifications+ 9 + 5 + 1 + 8 = 18314589938+ 9 +8 + 4 + 3 + 1 = 33 x 3 =1234500006 0123450000601234565 MSI/Plessey Specifications 195/11 = 17 remainder 9434578424,5,6,7,2,3,4,5,6,7 + 12 + 32 + 35 + 30 + 28 + 6 + 12 + 36 =RF Laser Setup Menu RF Laser SetupLink Test Code RSS-14 Code 35 Code 5 LengthSET Clear CodeStart Setup for Base only RF Base Station Setup MenuFull Ascii Menu 056 057 058 059 060 061 062 063 064 065 066 067 +T* *+U* *+V* *+W +X* *+Y* *+Z* *%P%R* *%S* *%T 33, 37, 38, 39, 43 IndexSee Appendix J UPC/EAN