Worth Data RF Laser Postamble, Bar Code Data Preamble Data Transmitted 123, XYZ123, 12345678

Page 18

The default is no preamble. To select a preamble, scan up to 15 characters from the "FULL ASCII MENU" on the back of the RF Laser Setup Menu, and then scan SET when you're done. To return to the no preamble setting, scan Clear here instead of scanning SET or any characters from the FULL ASCII MENU.

You can trim 1-15 leading characters from bar code codes by scanning a ~ (tilde -- ASCII 126) followed by a single digit, 1 through F, as part of the Preamble. (Bar codes that are shorter than the amount-to-trim are transmitted with no trimming.) Consider the examples in the following table to understand how trimming works:

Bar Code Data

Preamble

Data Transmitted

123

XYZ

XYZ123

12345678

~3XYZ

XYZ45678

12345678

~9

12345678

12345

~A

12345

123456

~5

6

You can also trim selectively by bar code type. For example, you can trim 2 characters from Code 39 and a different amount from other bar code outputs. This is done by using the bar code ID character in conjunction with the tilde (~). A preamble of ~b2~c1 says trim 2 characters from the front of Code 39 output and trim 1 character from the front of UPC-A. Refer to the Code 128 parameter on page 12 for a list of the ID character associated with each bar code type.

A final use of the Preamble/Postamble is to enter a minimum/maximum length check for bar code data read. Use the Preamble or Postamble by entering nnmm where "" is ASCII 124, "nn" is the two digit minimum to be read and "mm" is the two digit maximum to be read.

Postamble

"Postamble" refers to a user-specified data string transmitted at the end of each bar code. For instance, if you specify the postamble @@ and read data of 123456, "123456@@" would be transmitted to your computer.

The default is no postamble. To select a postamble, scan up to 15 characters from the "FULL ASCII MENU" on the back of the Reader Setup Menu, and then scan SET when you're done. To return to the no postamble setting, scan CLEAR here instead of scanning SET or any characters from the FULL ASCII MENU.

You can trim 1-15 trailing characters from bar code codes by scanning a ~ (tilde

--ASCII 126) followed by a single hex digit, 1 through F. (Bar codes which are shorter than the amount-to-trim are transmitted without trimming.) Consider the examples in the following table to understand the options of the Postamble:

15

Image 18
Contents Worth Data Inc August Page Table Of Contents Introduction Installation Components of RF Laser ReadersScanner Beeps and LEDs what they mean USB Installation Installing the R/F Reader with a dedicated serial port Installing the R/F Reader between a computer and terminal MenuF36, DB9 Straight Cable Pin-outs Laser Serial Model Pin-outsF34, DB25 Null Modem Cable ModUPC\EAN Laser Scanning Instructions Using The RF Laser Setup Menu Channel Code 3 of 9 CodeUPC/EAN Code Codabar Disable MSIMSI and Plessey 5 Code5 Data Length Beep OptionsPreamble XYZ123 PostambleBar Code Data Preamble Data Transmitted 123 12345678Characters Set ID CharacterLink Test Code Scan End Setup ResetScan Start Setup Scan Aiming Dot Duration Scan Start Setup Scan 2Scan Start Setup Scan Terminator Scan Start Setup Scan 2 of 5 CodeScan Start Setup Scan Code Parity Baud rateData bits Stop bitsTest the RF Laser with your computer Page Radio Considerations Operational DetailsRange Accumulate Mode Function/Control Key Support PC Key Full Ascii Menu Bar CodeWindows Key Command and Option Keys on Mac USB KeyboardsFunction keys F11 and F12 Full Ascii MenuReader wont beep when reading bar codes TroubleshootingAll Models Troubleshooting Poor read rateUSB Trouble Shooting Windows XPSerial Troubleshooting Reader doesnt beep when you try to read your bar codesData characters are garbled or missing Changing Jumpers and Channels Page Recharging the Batteries Specifications for Code American National Standards Institute Customer Service108/43 = 2 with a Remainder Table C-1. Mod 43 Check character calculation for Code+ 2 + 3 + 33 + 34 + 35 = Value 22 is the Check CharacterFull Ascii Extension to Code Table C-2. Full Ascii TableCode 93 Specifications Codabar Specifications A12345bCode 128 Specifications UCC-128/ EAN-128GS1 US Interleaved 2 of 5 Code Interleaved 2 of 5 Mod 10 check digit calculation60 57 = 019873UPC Specifications Isbn Specifications UPC 2 and 5-character supplemental codes33 x 3 = 18314589938+ 9 +8 + 4 + 3 + 1 = + 9 + 5 + 1 + 8 =1234500006 0123450000601234565 MSI/Plessey Specifications + 12 + 32 + 35 + 30 + 28 + 6 + 12 + 36 = 9434578424,5,6,7,2,3,4,5,6,7 195/11 = 17 remainderRF Laser Setup Menu RF Laser SetupLink Test Code 5 Length Code 35 Code RSS-14Code SET ClearRF Base Station Setup Menu Start Setup for Base onlyFull Ascii Menu 056 057 058 059 060 061 062 063 064 065 066 067 +T* *+U* *+V* *+W +X* *+Y* *+Z* *%P%R* *%S* *%T Index 33, 37, 38, 39, 43See Appendix J UPC/EAN