The default is no preamble. To select a preamble, scan up to 15 characters from the "FULL ASCII MENU" on the back of the RF Laser Setup Menu, and then scan SET when you're done. To return to the no preamble setting, scan Clear here instead of scanning SET or any characters from the FULL ASCII MENU.
You can trim
Bar Code Data | Preamble | Data Transmitted |
123 | XYZ | XYZ123 |
12345678 | ~3XYZ | XYZ45678 |
12345678 | ~9 | 12345678 |
12345 | ~A | 12345 |
123456 | ~5 | 6 |
You can also trim selectively by bar code type. For example, you can trim 2 characters from Code 39 and a different amount from other bar code outputs. This is done by using the bar code ID character in conjunction with the tilde (~). A preamble of ~b2~c1 says trim 2 characters from the front of Code 39 output and trim 1 character from the front of
A final use of the Preamble/Postamble is to enter a minimum/maximum length check for bar code data read. Use the Preamble or Postamble by entering nnmm where "" is ASCII 124, "nn" is the two digit minimum to be read and "mm" is the two digit maximum to be read.
Postamble
"Postamble" refers to a
The default is no postamble. To select a postamble, scan up to 15 characters from the "FULL ASCII MENU" on the back of the Reader Setup Menu, and then scan SET when you're done. To return to the no postamble setting, scan CLEAR here instead of scanning SET or any characters from the FULL ASCII MENU.
You can trim
--ASCII 126) followed by a single hex digit, 1 through F. (Bar codes which are shorter than the
15