Code 128 Specifications

Code 128 is a very powerful bar code, combining an extensive character set and variable length with compactness and error checking. The character set contains all 128 ASCII characters with each character made up of three bars and three spaces. Each element (bar or space) varies from one to four units in width, totaling 11 units of width per character. Code 128 contains two levels of error checking:

Each character is checked for internal parity, and

The last character is a checksum.

Code 128 has three subsets, A, B and C. Subset A contains alphanumeric characters and unprintable control characters, subset B contains alphanumeric characters plus printable control characters and subset C contains only numeric characters and uses a 2-character

12345 encoding scheme to create a more compact bar code. Code 128 uses an internal Mod 103 check character that

is not displayed by the bar code reader. Code 128 bar codes can be made up of only one subset or may be a combination of several.

The Code 39 features of Accumulate Mode, Caps Lock ON and Caps lock OFF also apply to Code 128.

UCC-128/ EAN-128

UCC-128/EAN-128 Code is a subset of Code 128 adopted by the UCC and EAN council’s for use as a shipping label symbology. UCC/EAN-128 bar codes always start with a Function Code 1 character. In addition, all variable length fields are terminated by a Function Code 1 character unless they are the last field in the bar code.

The RF Laser Reader outputs the following for the special function codes and start sequences:

]C1

Start C/Function Code 1

^]

(GS) Function Code 1 as a variable string terminator

If UCC/EAN 128 is enabled, the reader looks for the Start C/Function Code 1 to indicate a UCC/EAN 128 bar code.

The UCC Serial Shipping Container Code specification calls for a 19 digit UCC/EAN 128 code with an additional Mod 10 Check digit (20 digits in all).

37

Image 41
Contents Worth Data Inc August Page Table Of Contents Introduction Scanner Beeps and LEDs what they mean InstallationComponents of RF Laser Readers USB Installation Installing the R/F Reader with a dedicated serial port Menu Installing the R/F Reader between a computer and terminalF34, DB25 Null Modem Cable Laser Serial Model Pin-outsF36, DB9 Straight Cable Pin-outs ModUPC\EAN Laser Scanning Instructions Using The RF Laser Setup Menu Code 3 of 9 Code ChannelUPC/EAN Code MSI and Plessey Disable MSICodabar 5 CodePreamble 5 Data LengthBeep Options Bar Code Data Preamble Data Transmitted 123 PostambleXYZ123 12345678Link Test Code CharactersSet ID Character Scan Start Setup Scan Aiming Dot Duration ResetScan End Setup Scan Start Setup Scan 2Scan Start Setup Scan Code Scan Start Setup Scan TerminatorScan Start Setup Scan 2 of 5 Code Data bits Baud rateParity Stop bitsTest the RF Laser with your computer Page Range Radio ConsiderationsOperational Details Accumulate Mode PC Key Full Ascii Menu Bar Code Function/Control Key SupportFunction keys F11 and F12 Command and Option Keys on Mac USB KeyboardsWindows Key Full Ascii MenuAll Models Troubleshooting TroubleshootingReader wont beep when reading bar codes Poor read rateWindows XP USB Trouble ShootingReader doesnt beep when you try to read your bar codes Serial TroubleshootingData characters are garbled or missing Changing Jumpers and Channels Page Recharging the Batteries American National Standards Institute Customer Service Specifications for Code+ 2 + 3 + 33 + 34 + 35 = Table C-1. Mod 43 Check character calculation for Code108/43 = 2 with a Remainder Value 22 is the Check CharacterTable C-2. Full Ascii Table Full Ascii Extension to CodeCode 93 Specifications A12345b Codabar SpecificationsUCC-128/ EAN-128 Code 128 SpecificationsGS1 US Interleaved 2 of 5 Mod 10 check digit calculation Interleaved 2 of 5 Code019873 60 57 =UPC Specifications UPC 2 and 5-character supplemental codes Isbn Specifications+ 9 +8 + 4 + 3 + 1 = 1831458993833 x 3 = + 9 + 5 + 1 + 8 =01234565 123450000601234500006 MSI/Plessey Specifications 4,5,6,7,2,3,4,5,6,7 943457842+ 12 + 32 + 35 + 30 + 28 + 6 + 12 + 36 = 195/11 = 17 remainderLink Test Code RF Laser Setup MenuRF Laser Setup 5 Code Code 35 Length RSS-14SET Clear CodeStart Setup for Base only RF Base Station Setup MenuFull Ascii Menu 056 057 058 059 060 061 062 063 064 065 066 067 %R* *%S* *%T +T* *+U* *+V* *+W+X* *+Y* *+Z* *%P 33, 37, 38, 39, 43 IndexSee Appendix J UPC/EAN