DETAILED DESCRIPTION OF SET-UP MENUS
OPERATION
| Item |
| Setting |
| V | V |
|
|
|
| Description of setting | T | T |
No. | Item | No. | Item |
| R | R |
| 1 | 2 | ||||
|
|
|
|
| ||
|
|
|
|
|
|
|
108 | HUMID | 0000 | OFF | This selects whether condensation is to be ignored when it has formed and |
|
|
| OPE | 0001 | ON | operation is to be continued. |
|
|
|
|
|
| 0: Operation is disabled. |
|
|
|
|
|
| 1: Operation is enabled. Although operation is still possible even when con- |
|
|
|
|
|
| densation has formed, the unit’s operation cannot be guaranteed. |
| ª |
|
|
|
| <Note> |
| |
|
|
|
| Since the tape may be damaged or other trouble may occur when “1: |
|
|
|
|
|
| Operation is enabled” is selected, “0: Operation is disabled” is normally |
|
|
|
|
|
| selected. |
|
|
|
|
|
|
|
|
|
109 | SEARCH | 0000 | DIAL | This selects whether the direct search operation is to be performed. |
|
|
| ENA | 0001 | KEY | DIAL: Direct search mode |
| ª |
|
|
|
| KEY: No direct search mode (The search dial is operable in the STILL mode |
| |
|
|
|
|
|
| |
|
|
|
| only.) |
|
|
|
|
|
|
|
|
|
110 | AUTO REW | 0000 | OFF | This selects whether the tape is automatically rewound to the beginning when |
|
|
|
| 0001 | ON | the end of the tape is detected in the PLAY, REC, or SHTL modes. | ª | ª |
|
|
|
| 0: Transport stops at the end of the tape. | ||
|
|
|
|
|
| |
|
|
|
| 1: The tape is automatically rewound to the beginning. |
|
|
|
|
|
|
|
|
|
111 | ALL STOP SEL | 0000 | STOP | This is used to select the mode to which the unit is to be set when the ALL |
|
|
|
| 0001 | STILL | STOP button is pressed. |
| ª |
|
|
|
| 0: The unit is set to the STOP mode. |
| |
|
|
|
|
|
| |
|
|
|
| 1: The unit is set to the |
|
|
|
|
|
|
|
|
|
The underlined number and item are the factory settings.
Detailed description of
25