ERROR MESSAGES
Error No. | Details of error | VTR operation |
|
|
|
The | STOP | |
|
|
|
Abnormal tension has been detected. | STOP | |
|
|
|
At the tape start or end, the short FF or REW operation does not stop even after 7 | STOP | |
| or more seconds. |
|
|
|
|
A check sum error was detected in the serial data communication between the | STOP | |
| syscon and servo. |
|
|
|
|
In serial data communication between the syscon and servo, the data was fixed at | STOP | |
| low or high and the absence of data was detected. |
|
|
|
|
A communication error was detected in the serial data between the syscon and | STOP | |
| servo when the power was turned on. |
|
|
|
|
About an hour has elapsed after the fan motor stopped. The VTR forcibly turns off | Forced POWER OFF | |
| its power. |
|
|
|
|
The heat sensor was activated and an abnormally high temperature inside the | Forced POWER OFF | |
| VTR was detected. |
|
|
|
|
Trouble in the solenoid drive circuitry was detected. | Forced POWER OFF | |
|
|
|
Trouble in the cleaning solenoid drive circuitry was detected. | Forced POWER OFF | |
|
|
|
The input supply voltage dropped below the undercut voltage. | Forced POWER OFF (*) | |
|
|
|
(*) The counter display flashes to provide a warning.