Transcend Information TS64GSSD25S-M, TS128GSSD25S-M Smart Function Set B0h, Code Smart Subcommand

Page 31

TS8GSSD25S-S

 

TS16GSSD25S-S/M

 

TS32GSSD25S-S/M

 

TS64GSSD25S-S/M

 

TS128GSSD25S-M

2.5” Solid State Disk

TS192GSSD25S-M

SMART Function Set (B0h)

Performs different processing required for predicting device failures, according to the subcommand specified in the Features register. If the Features register contains an unsupported value, the Aborted Command error is returned. If the SMART function is disabled, any subcommand other than SMART ENABLE OPERATIONS results in the Aborted Command error.

Code

Smart Subcommand

D0h

READ DATA

D1h

READ ATTRIBUTE THRESHOLDS

D2h

ENABLE/DISABLE ATTRIBUTE AUTOSAVE

D3h

SAVE ATTRIBUTE VALUES

D5h

Reserved

D6h

Reserved

D8h

ENABLE OPERATIONS

D9h

DISABLE OPERATIONS

DAh

RETURN STATUS

Transcend Information Inc.

31

V1.08

Image 31
Contents V1.08 Placement FeaturesDimensions DescriptionSpecifications Sequential WriteMax Model P/N Sequential ReadMaxModel P/N User Max. LBA Cylinder Head Sector Operating Non-Operating Data Reliability Data RetentionCompliance Package Dimensions Pin Layout Pin AssignmentsPin No Pin Name Block Diagram Bad-block management ReliabilityWear-Leveling algorithm ECC algorithmSata Interface Out of bank signalingComreset TS192GSSD25S-M Cominit TS192GSSD25S-M Power on sequence Power on sequence timing diagramATA command register Command Name Code Command TableSET Features ATA Command Specifications Word Value Description Identify Device Information Default ValuePIO data transfer cycle timing mode Reserved TS192GSSD25S-M Minor version number TS192GSSD25S-M TS192GSSD25S-M Current AAM value 15-8 Vendor’s recommended AAM value 95-99 Read Buffer E4h Idle E3hIdle Immediate E1h Initialize Device Parameters 91hRead LOG EXT 2Fh Log Address Log Name Feature Set AccessRead DMA EXT 25h Read Fpdma Queued 60hRecalibrate 10h Security Disable Password F6hRead Verify Sectors 40h/41h Read Verify Sectors EXT 42hSecurity SET Password F1h Security set Password data contentSecurity Unlock F2h Features register Value and settable operating mode Smart Function Set B0h Code Smart SubcommandByte Description Byte 2-361 Individual attribute dataDescription Detail Information Byte Attribute ID information is listed in the following tableSmart Read Attribute Threshold Smart Enabl Operations Write DMA CAh Standby E2hStandby Immediate E0h Write Buffer E8hWrite Sectors EXT 34h Write Multiple EXT 39hWrite Multiple FUA EXT CEh Write Sectors 30h/31hTaiwan Germany Ordering Information