Dell DL4000 Environmental Temperature, Temperature Continuous Operation, Relative Humidity

Page 85

Expanded Operating Temperature

 

For temperatures between 40 °C and 45 °C, de-rate

 

maximum allowable dry bulb temperature by 1 °C per 125

 

m above 950 m (1 °F per 228 ft).

Expanded Operating Temperature Restrictions

• Do not perform a cold startup below 5 °C.

 

 

• The operating temperature specified is for a

 

maximum altitude of 3048 m (10,000 ft).

 

• GPU is not supported

 

• 130 W (4 core) and 135 W processor is not

 

supported

 

• Redundant power supplies are required

 

• Non Dell qualified peripheral cards and/or

 

peripheral cards greater than 25 W are not

 

supported

Environmental

NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.

Temperature

 

Maximum Temperature Gradient (Operating and

20 °C/h (36 °F/h)

Storage)

 

Storage Temperature Limits

–40 °C to 65 °C (–40 °F to 149 °F)

Temperature (Continuous Operation)

 

Temperature Ranges (for altitude less than 950 m or 3117 ft)

Humidity Percentage Range

10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment.

10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew point.

Relative Humidity

 

Storage

5% to 95% RH with 33 °C (91 °F) maximum dew point.

 

Atmosphere must be non-condensing at all times.

Maximum Vibration

 

Operating

0.26 Grms at 5 Hz to 350 Hz (all operation orientations).

Storage

1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides

 

tested).

Maximum Shock

 

Operating

One shock pulse in the positive z axis of 31 G for 2.6 ms in

 

all operational orientations.

Storage

Six consecutively executed shock pulses in the positive

 

and negative x, y, and z axes (one pulse on each side of

 

the system) of 71 G for up to 2 ms.

Maximum Altitude

 

85

Image 85
Contents Regulatory Model E16S Series Regulatory Type E16S001 Dell Inc Contents Installing The Cooling Shroud Using System Diagnostics Troubleshooting Your SystemTechnical Specifications System Messages Jumpers And ConnectorsGetting Help Indicator, Button, or Icon Description Connector Front-Panel Features And IndicatorsElectrical indicator Condition Diagnostic IndicatorsCorrective Action Error occurs Hard-Drive Indicator PatternsDrive-Status Condition Indicator Pattern RAID Only Amber if a memorySeconds Back-Panel Features And IndicatorsPower Indicator Codes NIC Indicator CodesGreen Link indicator is Other Information You May Need Guide Manuals Users Guide Getting StartedGuide Release Notes Page Entering System Setup Responding To Error Messages System Setup OptionsUsing The System Setup Navigation Keys System Setup Main ScreenSystem Information Screen Memory Settings ScreenProcessor Settings Screen Boot Settings Screen Sata Settings ScreenIntegrated Devices Screen Serial Communications Screen System Profile Settings ScreenSystem Security Screen Miscellaneous Settings Assigning a System And/Or Setup Password System And Setup Password FeaturesSet to Enabled Using Your System Password To Secure Your System Operating With a Setup Password Enabled IDRAC Settings UtilityEntering The iDRAC Settings Utility Embedded System ManagementFront Bezel Optional Recommended ToolsRemoving The Front Bezel Opening And Closing The System Installing The Front BezelOpening The System Closing The System Inside The SystemRemoving The Cooling Shroud Cooling ShroudSystem Memory Installing The Cooling ShroudChannel 0 slots A1, A5, and A9 ProcessorMode-Specific Guidelines Memory ConfigurationRemoving Memory Modules Number Dimm Rank Dimm Slot PopulationMemory module/memory-module blank Time Installing Memory ModulesHard Drives Installing The Memory ModuleRemoving a Hot-Swap Hard Drive Installing a Hot-Swap Hard DriveRemoving a Hard Drive From a Hard-Drive Carrier Cooling Fans Installing a Hard Drive Into a Hard-Drive CarrierRemoving a Cooling Fan Expansion Card Installation Guidelines Installing a Cooling FanExpansion Cards And Expansion-Card Risers Riser PCIe Slot Removing An Expansion CardHeight Length Link Width Slot Width Card Priority Card Type Slot Priority Max AllowedRemoving and Installing the Expansion Card Installing An Expansion CardRemoving Expansion-Card Risers Removing and Installing the Expansion Card RiserSD vFlash Card Installing Expansion-Card RisersReplacing An SD vFlash Card Internal Dual SD ModuleRemoving The Internal Dual SD Module Removing and Installing the Internal Dual SD Module Installing The Internal Dual SD ModuleInternal SD Card Installing An Internal SD CardIntegrated Storage Controller Card Removing An Internal SD CardRemoving The Integrated Storage Controller Network Daughter Card Installing The Integrated Storage ControllerRemoving The Network Daughter Card Processors Installing The Network Daughter CardRemoving a Processor Removing and Installing the Heat Sink Close-lock symbol Removing and Installing a Processor Installing a ProcessorYour system supports two 750 W power supplies Power SuppliesRemoving An AC Power Supply Hot Spare FeatureInstalling An AC Power Supply System BatteryReplacing The System Battery Removing the System Battery Cover Removing The Hard-Drive Backplane Hard-Drive BackplaneBackplane signal cable SD card socket Cabling Diagram-2.5 Inch Systems Installing The Hard-Drive BackplaneRemoving The Control Panel Control Panel AssemblyRemoving and Installing the Control Panel Installing The Control PanelRemoving The System Board System BoardSystem board System-board holder Release pin Installing The System Board Troubleshooting The Video Subsystem Troubleshooting External ConnectionsTroubleshooting a USB Device Troubleshooting a NIC Troubleshooting a Serial I/O DeviceTroubleshooting a Damaged System Troubleshooting a Wet SystemTroubleshooting Power Supplies Troubleshooting The System BatteryTroubleshooting Cooling Fans Troubleshooting Cooling ProblemsTroubleshooting System Memory Reseat the memory modules in their sockets Close the system Troubleshooting An SD CardTroubleshooting a Storage Controller Troubleshooting a Hard DriveTroubleshooting Expansion Cards Troubleshooting Processors Page When To Use The Embedded System Diagnostics Dell Online Diagnostics Dell Embedded System DiagnosticsRunning The Embedded System Diagnostics Least one event description is recorded System Diagnostic ControlsJumper Setting Description System Board Jumper SettingsConnector Description System Board ConnectorsJCOM1 Disabling a Forgotten Password Configuration High Capacity Expansion slots using riser cardConfiguration Drives Connectors BackExpanded Operating Temperature Connectors High CapacityFront InternalTemperature Continuous Operation Environmental TemperatureRelative Humidity Maximum VibrationOperating Altitude De-rating EnvironmentalParticulate Contamination Gaseous ContaminationSystem Error Messages ASR0002 Message ASR0001 MessageASR0003 Message BAT0002 MessageCPU0005 Message CPU0001 MessageCPU0010 Message CPU0023 MessageException is external to the processor CPU0701 Message CPU number protocol error detected DetailsCPU0702 Message CPU0703 MessageFAN0000 Message Action Reinstall or reconnect the hardware HWC2003 MessageDetails Fan operating speed is out of range Action FAN0001 MessageMEM0007 Message MEM0001 MessageMEM0701 Message MEM0702 MessagePCI1302 Message MEM8000 MessagePCI1304 Message PCI1308 MessagePDR0001 Message Fault detected on drive number Details Reinstall the deviceConfigurations PSU0001 Message Power supply number failed ActionPSU0003 Message PSU0002 MessagePSU0006 Message PSU0016 MessagePSU0034 Message PSU0033 MessagePSU0035 Message PSU0036 MessageSystem power inventory change PSU1201 Message Power supply redundancy is lost DetailsConfiguration and power consumption System power consumptionRFM1201 Message RFM1014 MessageRFM2001 Message RFM2002 MessageAppear if the user disabled event logging SEL0006 Message All event logging is disabled DetailsPower. If problem persists call support Issues persists, contact supportFailed TMP0119 MessageFailures TMP0121 MessageAlert Messages Diagnostic Messages102 Contacting Dell Locating Your System Service TagDocumentation Feedback
Related manuals
Manual 11 pages 38.93 Kb Manual 4 pages 41.95 Kb

DL4000 specifications

The Dell DL4000 is an innovative and robust data protection solution designed to meet the storage and backup needs of modern businesses. This appliance, part of Dell's Data Domain family, provides reliable data backup, recovery, and archiving, enhancing efficiency in managing critical business data.

One of the standout features of the DL4000 is its integration of advanced deduplication technology. This allows businesses to significantly reduce the amount of storage required for backup data by eliminating duplicate copies of files. The result is reduced storage costs and improved backup speeds, enabling organizations to save both time and resources.

The DL4000 also boasts scalable capacity, which is essential for growing businesses. With the ability to increase storage volume without significant infrastructure changes, organizations can easily adapt the appliance to changing data requirements. The product is available in various configurations, offering flexible options to meet diverse business needs.

Another key characteristic is its high performance in data protection tasks. The DL4000 provides quick backup and recovery capabilities, thanks to its efficient data processing algorithms. Organizations can restore critical data swiftly, minimizing downtime and ensuring business continuity in the event of data loss. The appliance supports multiple backup sources, including virtual machines, physical servers, and cloud environments, providing flexibility in data management.

Additionally, the DL4000 is equipped with robust security features. It supports encryption both at rest and in transit, ensuring that sensitive data is protected from unauthorized access. Compliance with industry regulations is simplified, aiding organizations in maintaining data integrity and confidentiality.

User-friendliness is another highlight of the Dell DL4000. The intuitive management interface allows IT administrators to monitor and manage backups with ease. Automation features help streamline backup processes, reducing the likelihood of human error and ensuring consistent data protection.

In conclusion, the Dell DL4000 offers a comprehensive data protection solution that combines advanced technologies with user-centric design. Its deduplication capabilities, scalability, high performance, security features, and ease of use make it an ideal choice for businesses looking to enhance their data backup and recovery strategies. Organizations investing in the DL4000 can be confident that they are adopting a powerful tool to safeguard their valuable data assets.