Dell DL4000 owner manual Installing Memory Modules, Time

Page 35

7.Install the cooling shroud.

8.Close the system.

9.Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Installing Memory Modules

WARNING: The memory modules are hot to the touch for some time after the system has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components or gold contacts on the memory module.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any memory socket that is not occupied. Remove memory-module blanks only if you intend to install memory modules in those sockets.

1.Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2.Open the system.

3.If applicable, remove the cooling shroud.

4.Locate the memory-module sockets.

CAUTION: Handle each memory module only by the card edges, making sure not to touch the middle of the memory module or gold contacts. To avoid damaging the memory module, handle only one memory module at

atime.

5.If a memory module or a memory-module blank is installed in the socket, remove it.

NOTE: Retain removed memory-module blank(s) for future use.

6.Align the memory-module's edge connector with the alignment key of the memory-module socket, and insert the memory module in the socket.

NOTE: The memory-module socket has an alignment key that allows you to install the memory module in the socket in only one orientation.

CAUTION: To prevent damage to the memory-module socket during installation, apply pressure at both ends of the memory module evenly. Do not apply pressure to the center of the memory module.

7.Press down on the memory module with your thumbs until the memory module snaps into place.

35

Image 35
Contents Regulatory Model E16S Series Regulatory Type E16S001 Dell Inc Contents Installing The Cooling Shroud Using System Diagnostics Troubleshooting Your SystemGetting Help Jumpers And ConnectorsTechnical Specifications System Messages Indicator, Button, or Icon Description Connector Front-Panel Features And IndicatorsCorrective Action Diagnostic IndicatorsElectrical indicator Condition Amber if a memory Hard-Drive Indicator PatternsError occurs Drive-Status Condition Indicator Pattern RAID OnlySeconds Back-Panel Features And IndicatorsGreen Link indicator is NIC Indicator CodesPower Indicator Codes Other Information You May Need Guide Release Notes Getting StartedGuide Manuals Users Guide Page Entering System Setup System Setup Main Screen System Setup OptionsResponding To Error Messages Using The System Setup Navigation KeysSystem Information Screen Memory Settings ScreenProcessor Settings Screen Boot Settings Screen Sata Settings ScreenIntegrated Devices Screen Serial Communications Screen System Profile Settings ScreenSystem Security Screen Miscellaneous Settings Set to Enabled System And Setup Password FeaturesAssigning a System And/Or Setup Password Using Your System Password To Secure Your System Embedded System Management IDRAC Settings UtilityOperating With a Setup Password Enabled Entering The iDRAC Settings UtilityRemoving The Front Bezel Recommended ToolsFront Bezel Optional Opening The System Installing The Front BezelOpening And Closing The System Closing The System Inside The SystemRemoving The Cooling Shroud Cooling ShroudSystem Memory Installing The Cooling ShroudChannel 0 slots A1, A5, and A9 ProcessorNumber Dimm Rank Dimm Slot Population Memory ConfigurationMode-Specific Guidelines Removing Memory ModulesMemory module/memory-module blank Time Installing Memory ModulesHard Drives Installing The Memory ModuleRemoving a Hot-Swap Hard Drive Installing a Hot-Swap Hard DriveRemoving a Hard Drive From a Hard-Drive Carrier Removing a Cooling Fan Installing a Hard Drive Into a Hard-Drive CarrierCooling Fans Expansion Cards And Expansion-Card Risers Installing a Cooling FanExpansion Card Installation Guidelines Card Priority Card Type Slot Priority Max Allowed Removing An Expansion CardRiser PCIe Slot Height Length Link Width Slot WidthRemoving and Installing the Expansion Card Installing An Expansion CardRemoving Expansion-Card Risers Removing and Installing the Expansion Card RiserSD vFlash Card Installing Expansion-Card RisersRemoving The Internal Dual SD Module Internal Dual SD ModuleReplacing An SD vFlash Card Removing and Installing the Internal Dual SD Module Installing The Internal Dual SD ModuleRemoving An Internal SD Card Installing An Internal SD CardInternal SD Card Integrated Storage Controller CardRemoving The Integrated Storage Controller Removing The Network Daughter Card Installing The Integrated Storage ControllerNetwork Daughter Card Processors Installing The Network Daughter CardRemoving a Processor Removing and Installing the Heat Sink Close-lock symbol Removing and Installing a Processor Installing a ProcessorYour system supports two 750 W power supplies Power SuppliesRemoving An AC Power Supply Hot Spare FeatureReplacing The System Battery System BatteryInstalling An AC Power Supply Removing the System Battery Cover Removing The Hard-Drive Backplane Hard-Drive BackplaneBackplane signal cable SD card socket Cabling Diagram-2.5 Inch Systems Installing The Hard-Drive BackplaneRemoving The Control Panel Control Panel AssemblyRemoving and Installing the Control Panel Installing The Control PanelRemoving The System Board System BoardSystem board System-board holder Release pin Installing The System Board Troubleshooting a USB Device Troubleshooting External ConnectionsTroubleshooting The Video Subsystem Troubleshooting a NIC Troubleshooting a Serial I/O DeviceTroubleshooting a Damaged System Troubleshooting a Wet SystemTroubleshooting Power Supplies Troubleshooting The System BatteryTroubleshooting System Memory Troubleshooting Cooling ProblemsTroubleshooting Cooling Fans Reseat the memory modules in their sockets Close the system Troubleshooting An SD CardTroubleshooting a Storage Controller Troubleshooting a Hard DriveTroubleshooting Expansion Cards Troubleshooting Processors Page Running The Embedded System Diagnostics Dell Online Diagnostics Dell Embedded System DiagnosticsWhen To Use The Embedded System Diagnostics Least one event description is recorded System Diagnostic ControlsJumper Setting Description System Board Jumper SettingsConnector Description System Board ConnectorsJCOM1 Disabling a Forgotten Password Connectors Back Expansion slots using riser cardConfiguration High Capacity Configuration DrivesInternal Connectors High CapacityExpanded Operating Temperature FrontMaximum Vibration Environmental TemperatureTemperature Continuous Operation Relative HumidityGaseous Contamination EnvironmentalOperating Altitude De-rating Particulate ContaminationSystem Error Messages BAT0002 Message ASR0001 MessageASR0002 Message ASR0003 MessageCPU0023 Message CPU0001 MessageCPU0005 Message CPU0010 MessageCPU0703 Message CPU0701 Message CPU number protocol error detected DetailsException is external to the processor CPU0702 MessageFAN0001 Message Action Reinstall or reconnect the hardware HWC2003 MessageFAN0000 Message Details Fan operating speed is out of range ActionMEM0702 Message MEM0001 MessageMEM0007 Message MEM0701 MessagePCI1308 Message MEM8000 MessagePCI1302 Message PCI1304 MessagePSU0001 Message Power supply number failed Action Reinstall the devicePDR0001 Message Fault detected on drive number Details ConfigurationsPSU0016 Message PSU0002 MessagePSU0003 Message PSU0006 MessagePSU0036 Message PSU0033 MessagePSU0034 Message PSU0035 MessageSystem power consumption PSU1201 Message Power supply redundancy is lost DetailsSystem power inventory change Configuration and power consumptionRFM2002 Message RFM1014 MessageRFM1201 Message RFM2001 MessageIssues persists, contact support SEL0006 Message All event logging is disabled DetailsAppear if the user disabled event logging Power. If problem persists call supportTMP0121 Message TMP0119 MessageFailed FailuresAlert Messages Diagnostic Messages102 Documentation Feedback Locating Your System Service TagContacting Dell
Related manuals
Manual 11 pages 38.93 Kb Manual 4 pages 41.95 Kb

DL4000 specifications

The Dell DL4000 is an innovative and robust data protection solution designed to meet the storage and backup needs of modern businesses. This appliance, part of Dell's Data Domain family, provides reliable data backup, recovery, and archiving, enhancing efficiency in managing critical business data.

One of the standout features of the DL4000 is its integration of advanced deduplication technology. This allows businesses to significantly reduce the amount of storage required for backup data by eliminating duplicate copies of files. The result is reduced storage costs and improved backup speeds, enabling organizations to save both time and resources.

The DL4000 also boasts scalable capacity, which is essential for growing businesses. With the ability to increase storage volume without significant infrastructure changes, organizations can easily adapt the appliance to changing data requirements. The product is available in various configurations, offering flexible options to meet diverse business needs.

Another key characteristic is its high performance in data protection tasks. The DL4000 provides quick backup and recovery capabilities, thanks to its efficient data processing algorithms. Organizations can restore critical data swiftly, minimizing downtime and ensuring business continuity in the event of data loss. The appliance supports multiple backup sources, including virtual machines, physical servers, and cloud environments, providing flexibility in data management.

Additionally, the DL4000 is equipped with robust security features. It supports encryption both at rest and in transit, ensuring that sensitive data is protected from unauthorized access. Compliance with industry regulations is simplified, aiding organizations in maintaining data integrity and confidentiality.

User-friendliness is another highlight of the Dell DL4000. The intuitive management interface allows IT administrators to monitor and manage backups with ease. Automation features help streamline backup processes, reducing the likelihood of human error and ensuring consistent data protection.

In conclusion, the Dell DL4000 offers a comprehensive data protection solution that combines advanced technologies with user-centric design. Its deduplication capabilities, scalability, high performance, security features, and ease of use make it an ideal choice for businesses looking to enhance their data backup and recovery strategies. Organizations investing in the DL4000 can be confident that they are adopting a powerful tool to safeguard their valuable data assets.