MGE UPS Systems Switched PDU Resetting to Factory Defaults, Uploading Firmware, Appendices

Page 57
Resetting to Factory Defaults

5. Appendices

Resetting to Factory Defaults

You may reset the non-volatile RAM that stores all configurable options. This clears all administrator-editable fields and resets all command line configurable options to their default values, including all user accounts.

You may reset the unit to factory defaults from the command line or the HTML interface, or by pressing the reset button. You must have administrator-level privileges to issue the command. Using the reset button may be necessary when a forgotten password prevents administrator login. Each of the methods updates the current working configuration to the factory defaults.

NOTE: Resetting the unit resets all TCP/IP and Telnet/Web configurations. Reconfiguring the TCP/IP and Telnet/web settings will be required.

To reset to factory defaults from the HTML interface

On the Restart page in the Tools section of the HTML interface, select Restart and reset to factory defaults from the drop-down menu and press Apply.

To reset to factory defaults from the command line

At the Switched PDU: prompt, type restart factory and press Enter.

To reset to factory defaults using the reset button

Locate the recessed reset button directly beside the Serial & Ethernet ports. You will need a non-conductive, non-metallic tool that fits inside the recess.

Insert the tool in the recess, then depress and hold the reset button for at least ten seconds.

NOTE: If the reset button is depressed and held for more than 15 seconds, the reset will abort.

Uploading Firmware

You may upload new versions of firmware using File Transfer Protocol (FTP). This allows access to new firmware releases for firmware improvements and new features additions.

NOTE: To begin an FTP upload session, you must first configure the FTP Host address, username/password, filename and filepath. For information on configuring the FTP settings required for firmware upload see FTP Administration on page 41.

You may initiate an FTP upload session by issuing a command or from the HTML interface. You must have administrator-level privileges to initiate an upload.

To initiate an FTP upload session from the HTML interface

On the Restart page in the Tools section of the HTML interface, select Restart and upload firmware via FTP from the drop-down menu and press Apply.

Upon issuing this command the unit will restart and upload the firmware file specified with the FTP Filename command from the previously configured FTP Host. See See FTP Administration on page 41 for more information.

To initiate an FTP upload session from the command line

The Restart FTPLoad command initiates an upload of firmware. Upon issuing this command the unit will restart and upload the firmware file specified with the FTP Filename command from the previously configured FTP Host. See FTP Administration on page 41 for more information.

To initiate an FTP firmware upload session:

At the Switched PDU: prompt, type restart ftpload and press Enter.

301-0399-4 Rev A. - Page 57

Image 57
Contents E T N I N U E H T Switched PDU Installation and user manualDangerous Voltage InstructionsProtective Grounding Terminal Life-Support PolicyINSTALLATION ContentsGETTING STARTED OPERATIONS1. Getting Started Quick Start Guideuser account prior to attachment to your network 2. Installation Standard AccessoriesAdditional Required Items Figure 1. Unit Views Equipment Overview1 Power Input 2 Input Current LED 3 Ethernet / RS232 Ports 4 Temperature / Humidity PortsInstalling the Power Input Retention Bracket Safety PrecautionsFigure 2. Retention Bracket assembly To install the power input retention bracketTo attach a power cord to the unit Connecting to the Power SourceTo connect to the power source MountingConnecting the Sensors Connecting DevicesConnecting to the Unit Serial RS232 portPage I NTERFACES 3. OperationsHTML I NTERFACE C OMMAND L INE I NTERFACE3. Operations Usernames and PasswordsInterfaces Outlet Naming and GroupingHTML Interface Figure 4. Example HTML page Logging InTo log in by HTML Individual Outlet ControlGroup Outlet State/Control State Field ValuesEnvironmental Monitoring ConfigurationInput Load SensorsTelnet/SSH NetworkHTTP/SSL Setting the IP address, subnet mask or gatewaySetting the HTTP authentication method Serial PortsSetting SSL access level Setting the data-rate for the serial portsGroups OutletsUsers Changing a user passwordAdding and Deleting outlet access Changing a user’s access privilege levelAdding and Deleting group access Adding and Deleting serial port accessSNMP SNTPSetting the filename for upload Testing the FTP upload configurationTools Command Line InterfaceRestart Logging InAdministrative Command Summary Operations Command SummaryAdministrative Command Summary continued To display the names of commands that you may executeRebooting outlets Operations CommandsTo reboot one or more outlets Turning outlets onTo display on/off status of one or more outlets Displaying outlet statusTo display accessible outlets Displaying accessible outletsDisplaying accessible groups To display accessible groupsTo display accessible serial ports Displaying accessible serial portsConnecting to a serial device Displaying infeed statusTo display the status of the Environmental Monitor Displaying the status of the Environmental MonitorStarting a new session To start a new sessionUser Administration Administration CommandsCreating a user account To create a user accountTo change a password Changing a passwordSetting user access level privileges To set the access level privilege for a userTo display user access privilege levels Displaying the access privilege levelsAdding outlet access to a user To grant outlet access to a userTo delete outlet access for a user Deleting outlet access for a userAdding group access to a user To grant group access to a userDisplaying user outlet, group and serial port access Group AdministrationTo display user outlet, group and serial port access Creating a group nameAdding an outlet to a group Outlet AdministrationTo add an outlet to a group Deleting an outlet from a groupTo set the wakeup state Setting the outlet wakeup stateDisplaying outlet information To display outlet informationSetting the serial ports data-rate Serial Port AdministrationEnabling or disabling active signal checking for serial connections To enable or disable active signal checking for serial connectionsDisplaying system configuration information System AdministrationTo display system configuration information Creating a location descriptionTo create a tower name Creating a descriptive tower nameDisplaying tower information To display tower informationTo perform a warm boot TCP/IP AdministrationSetting the IP address Setting the subnet maskDisplaying network configuration information HTTP AdministrationTo display network configuration information To enable or disable HTTP supportFTP Administration Telnet AdministrationTo set the HTTP authentication method To enable or disable Telnet supportTo set the FTP password Setting the FTP PasswordSetting the filename to be uploaded Setting the filepath for the file to be uploadedSetting the SNTP server address SNTP AdministrationDisplaying SNTP configuration information To display SNTP configuration informationSSL Technical Specifications Enabling and Setting up SSL SupportEnabling and Setting up SSH Support SSH Technical SpecificationsEnabling and Setting up SSL Support SSL Command SummarySSL Technical Specifications To enable or disable SSL supportEnabling and Setting up SSH Support SSH Command SummarySSH Technical Specifications To enable or disable SSH supportEnabling and Setting up SNMP Support SNMP Command SummarySNMP To enable SNMP supportTo set the trap timer To reset the trap destinationSetting the Get/Set community strings Setting the Trap community stringTrap Summary SNMP TrapsTower Status traps Infeed Status trapsEnvironmental Monitor Status traps Outlet Status trapsTemperature/Humidity Sensor Status traps Load trapsHumidity traps Temp trapsTemp Trap Humidity TrapConfiguring Traps SNMP Trap Command Summary To Enable or Disable a Status trapEnabling or Disabling a Status trap Setting the Infeed Load limit To Enable or Disable a Load trapTo Enable or Disable a Change trap To Enable or Disable the Temp trapTo Enable or Disable the Humid trap Setting the Temperature sensor threshold limitsSetting the Humidity sensor threshold limits To set the Temperature threshold limitsTo display trap information Displaying trap configuration informationStatus WebServer15. Appendices R ESETTING TO F ACTORY D EFAULTSU PLOADING F IRMWARE T ECHNICAL S PECIFICATIONSTo reset to factory defaults from the HTML interface Resetting to Factory DefaultsTo reset to factory defaults from the command line To reset to factory defaults using the reset buttonPower Ratings Technical SpecificationsPhysical Specifications Models Europe/AsiaData Connections LED IndicatorsBranch Circuit Protection RS-232 portPage