MGE UPS Systems Switched PDU Technical Specifications, Models Europe/Asia, Americas, Appendices

Page 58
Technical Specifications

5. Appendices

Technical Specifications

Models

Europe/Asia

Model

Voltage

Inlet

Cordset (10’)

 

Outlets

RSNM-R8-E02

230V, 60Hz

IEC 60320/C20

*

8

IEC 60320/C13

 

 

 

 

 

RSMS-R8-E02

230V, 60Hz

IEC 60320/C20

*

8 IEC 60320/C13

 

 

 

 

 

RSNM-T16-E02

230V, 60Hz

IEC 60320/C20

*

16 IEC 60320/C13

 

 

 

 

 

 

RSMS-T16-E02

230V, 60Hz

IEC 60320/C20

*

16

IEC 60320/C13

Americas

Model

Voltage

Inlet

Cordset

 

Outlets

RSNM-R8-102

100-120V, 50/60Hz

IEC 60320/C20

*

 

8 NEMA 5-20R

 

 

 

 

 

 

RSMS-R8-102

100-120V, 50/60Hz

IEC 60320/C20

*

 

8 NEMA 5-20R

 

 

 

 

 

 

RSNM-R8-202

208-240V, 50/60Hz

IEC 60320/C20

*

8

IEC 60320/C13

 

 

 

 

 

 

RSMS-R8-202

208-240V, 50/60Hz

IEC 60320/C20

*

8

IEC 60320/C13

 

 

 

 

 

RSNM-T16-102

100-120V, 50/60Hz

IEC 60320/C20

*

16 NEMA 5-20R

 

 

 

 

 

RSMS-T16-102

100-120V, 50/60Hz

IEC 60320/C20

*

16 NEMA 5-20R

 

 

 

 

 

 

RSNM-T16-202

208-240V, 50/60Hz

IEC 60320/C20

*

16

IEC 60320/C13

 

 

 

 

 

 

RSMS-T16-202

208-240V, 50/60Hz

IEC 60320/C20

*

16

IEC 60320/C13

* Input cordset selected at time of purchase.

Power Ratings

 

 

Input Current Ratings1

 

 

Output Current Ratings

 

 

 

 

L’indice du courant d’entrée

 

 

L’indice du courant de sortie

 

 

 

 

Eingangsstromstärke

 

 

Ausgangsstromstärke

 

 

Model

 

Voltage

Current

Outlet

Branch2

Total

Modele

 

Tension

Courrant

Prise

 

Total

Modell

 

Spannung

Strom

Anschlussstelle

Insgesamt

RSNx-R8-102

 

100-120V 50/60Hz

16

 

16

16

16

 

RSNx-T16-102

 

 

 

 

 

 

 

 

 

 

 

RSNx-R8-202

 

208-240V 60Hz

16

 

12

16

16

 

RSNx-T16-202

 

 

 

 

 

 

 

 

 

 

 

RSNx-R8-E02

 

230V 50/60Hz

20

 

10

20

20

 

RSNx-T16-E02

 

 

 

 

 

 

 

 

 

 

 

1All current ratings are in amperes. Tous les indices de courant sont en ampères. Alle Angaben der Stromstärke erfolgen in Ampere.

21-8, 9-16

Physical Specifications

 

Operating

 

 

Storage

 

 

 

Temperature

32° to 122° F

(0° to 50° C)

-40° to 185° F

(-40° to 85° C)

 

 

 

 

 

Elevation(above MSL)

0 to 10,000 ft

(0 to 3000m)

0 to 50,000 ft

(0 to 15000m)

 

 

 

Relative Humidity

10 to 90%, non-condensing

10 to 90%, non-condensing

 

 

 

 

 

 

 

Dimensions (H x W x D)

 

 

Weight

 

 

 

 

 

 

RSNx-T16

45.5 x 1.75 x 2.25 in.

(1156 x 44 x 57 mm)

7.5 lbs

(16.5 kg)

RSNx-R8

1.75 x 17.0 x 7.0 in.

(44 x 437 x 177 mm)

6.75 lbs

(14.9 kg)

Page 58 - 301-0399-4 Rev A.

Image 58
Contents Switched PDU Installation and user manual E T N I N U E H TProtective Grounding Terminal InstructionsDangerous Voltage Life-Support PolicyGETTING STARTED ContentsINSTALLATION OPERATIONSQuick Start Guide 1. Getting Starteduser account prior to attachment to your network Standard Accessories 2. InstallationAdditional Required Items 1 Power Input 2 Input Current LED 3 Ethernet / RS232 Ports Equipment OverviewFigure 1. Unit Views 4 Temperature / Humidity PortsFigure 2. Retention Bracket assembly Safety PrecautionsInstalling the Power Input Retention Bracket To install the power input retention bracketTo connect to the power source Connecting to the Power SourceTo attach a power cord to the unit MountingConnecting to the Unit Connecting DevicesConnecting the Sensors Serial RS232 portPage HTML I NTERFACE 3. OperationsI NTERFACES C OMMAND L INE I NTERFACEInterfaces Usernames and Passwords3. Operations Outlet Naming and GroupingFigure 4. Example HTML page Logging In HTML InterfaceTo log in by HTML Group Outlet ControlIndividual Outlet State/Control State Field ValuesInput Load ConfigurationEnvironmental Monitoring SensorsHTTP/SSL NetworkTelnet/SSH Setting the IP address, subnet mask or gatewaySetting SSL access level Serial PortsSetting the HTTP authentication method Setting the data-rate for the serial portsUsers OutletsGroups Changing a user passwordAdding and Deleting group access Changing a user’s access privilege levelAdding and Deleting outlet access Adding and Deleting serial port accessSetting the filename for upload SNTPSNMP Testing the FTP upload configurationRestart Command Line InterfaceTools Logging InOperations Command Summary Administrative Command SummaryTo display the names of commands that you may execute Administrative Command Summary continuedTo reboot one or more outlets Operations CommandsRebooting outlets Turning outlets onDisplaying outlet status To display on/off status of one or more outletsDisplaying accessible groups Displaying accessible outletsTo display accessible outlets To display accessible groupsConnecting to a serial device Displaying accessible serial portsTo display accessible serial ports Displaying infeed statusStarting a new session Displaying the status of the Environmental MonitorTo display the status of the Environmental Monitor To start a new sessionCreating a user account Administration CommandsUser Administration To create a user accountSetting user access level privileges Changing a passwordTo change a password To set the access level privilege for a userAdding outlet access to a user Displaying the access privilege levelsTo display user access privilege levels To grant outlet access to a userAdding group access to a user Deleting outlet access for a userTo delete outlet access for a user To grant group access to a userTo display user outlet, group and serial port access Group AdministrationDisplaying user outlet, group and serial port access Creating a group nameTo add an outlet to a group Outlet AdministrationAdding an outlet to a group Deleting an outlet from a groupDisplaying outlet information Setting the outlet wakeup stateTo set the wakeup state To display outlet informationEnabling or disabling active signal checking for serial connections Serial Port AdministrationSetting the serial ports data-rate To enable or disable active signal checking for serial connectionsTo display system configuration information System AdministrationDisplaying system configuration information Creating a location descriptionDisplaying tower information Creating a descriptive tower nameTo create a tower name To display tower informationSetting the IP address TCP/IP AdministrationTo perform a warm boot Setting the subnet maskTo display network configuration information HTTP AdministrationDisplaying network configuration information To enable or disable HTTP supportTo set the HTTP authentication method Telnet AdministrationFTP Administration To enable or disable Telnet supportSetting the filename to be uploaded Setting the FTP PasswordTo set the FTP password Setting the filepath for the file to be uploadedDisplaying SNTP configuration information SNTP AdministrationSetting the SNTP server address To display SNTP configuration informationEnabling and Setting up SSH Support Enabling and Setting up SSL SupportSSL Technical Specifications SSH Technical SpecificationsSSL Technical Specifications SSL Command SummaryEnabling and Setting up SSL Support To enable or disable SSL supportSSH Technical Specifications SSH Command SummaryEnabling and Setting up SSH Support To enable or disable SSH supportSNMP SNMP Command SummaryEnabling and Setting up SNMP Support To enable SNMP supportSetting the Get/Set community strings To reset the trap destinationTo set the trap timer Setting the Trap community stringTower Status traps SNMP TrapsTrap Summary Infeed Status trapsTemperature/Humidity Sensor Status traps Outlet Status trapsEnvironmental Monitor Status traps Load trapsTemp Trap Temp trapsHumidity traps Humidity TrapTo Enable or Disable a Status trap Configuring Traps SNMP Trap Command SummaryEnabling or Disabling a Status trap To Enable or Disable a Change trap To Enable or Disable a Load trapSetting the Infeed Load limit To Enable or Disable the Temp trapSetting the Humidity sensor threshold limits Setting the Temperature sensor threshold limitsTo Enable or Disable the Humid trap To set the Temperature threshold limitsStatus Displaying trap configuration informationTo display trap information WebServer1U PLOADING F IRMWARE R ESETTING TO F ACTORY D EFAULTS5. Appendices T ECHNICAL S PECIFICATIONSTo reset to factory defaults from the command line Resetting to Factory DefaultsTo reset to factory defaults from the HTML interface To reset to factory defaults using the reset buttonPhysical Specifications Technical SpecificationsPower Ratings Models Europe/AsiaBranch Circuit Protection LED IndicatorsData Connections RS-232 portPage