MGE UPS Systems 30A user manual Access to control and connections

Page 8

1. Presentation

1.3 Access to control and connections

Upsilon STS 30 - 60 - 100 - 160 - 250 A (cabinet 1400 mm high)

1 Switch Q1 for Source S1

2 Circuit breaker Q5 for control electronics power supply

3 Circuit breaker Q6 for control electronics power supply

4 Switch Q2 for Source S2

5 Communication card cage

6 Bypass switch Q1BP for Source S1

7 Output switch Q3

16 Emergency power off terminal block

8 Bypass switch Q2BP for Source S2

9 Source S2 connection

10 Output connections

11 Source S1 connection

12 Earth bar

13 Connection cover

14 Base panels

15 Adjustable foot pads

Upsilon STS 30 - 60 - 100 - 160 - 250 - 400 - 600 A (cabinet 1900 mm high)

1

Switch Q1 for Source S1

2

Circuit breaker Q5 for control electronics

 

power supply

3

Circuit breaker Q6 for control electronics

 

power supply

4

Switch Q2 for Source S2

5

Communication card cage

6

Bypass switch Q1BP for Source S1

7

Output switch Q3

8

Bypass switch Q2BP for Source S2

16

Emergency power off terminal block

9

Source S2 connection

10

Output connections

11

Source S1 connection

12

Earth bar

13

Connection cover

14

Base panels

15

Adjustable foot pad

Page 8 - 34020113EN/AA

Image 8
Contents Upsilon STS 2 34020113EN/AA Introduction Using this document ForewordPictograms DocumentContents Appendix Presentation Upsilon STS 30 60 100 160 250 a cabinet 1400 mm highAccess to control and connections Upsilon STS 30 60 100 160 250 a cabinet 1400 mm highMan / machine interface Function buttonsOutput terminal block Relay communication cardJBus communication card Installation PositioningPower connections Upsilon STS 30 to 250 a Input Phases + PEN Output L1 L2 L3 Upsilon STS 400 to 600 a Input Phases + PEN Output Connection of the emergency power off terminal block Connection of the communication cards Connection of the Jbus communication cardRS232 RS485Connection of the relay communication card Characteristics of the output contactsCharacteristics of the input contacts Load is not supplied with power OperationStart-up ShutdownNormal mode. Operation on preferred source S1 Operation on the preferred sourceAutomatic transfer to the alternate source Manual transfer to the alternate sourceManual transfer to an out-of-phase alternate source Display screens Main screenFactory setting Customization Upsilon STS customizationCustomization of the relay communication card Inputs Factory settingSignals available on each contact Transfer to the manual bypass MaintenanceIdentification of anomalies UPS recycling at the end of service life EnvironmentAppendix Simplified diagram of an installation Simplified diagramsUpsilon STS simplified diagram Glossary Index Connections