APC ACRP101, ACRP501 manual Control Console Menus, Menu structure, Main menu, Device Manager option

Page 19

Control Console Menus

Menu structure

The menus in the control console list options by number and name. To use an option, type the option’s number and press ENTER, then follow any on-screen instructions.

For menus that allow you to change a setting you must use the Accept Changes option to save the changes you made. Some changes may only take effect after you log off.

While in a menu, you can also do the following:

Type ? and press ENTER to access a brief menu of option descriptions (if the menu has help available).

Press ENTER to refresh the menu.

Press ESC to return to the menu from which you accessed the current menu.

Press CTRL+C to return to the main (control console) menu.

Press CTRL+L to access the event log.

For more information about the event log, see “Events” on page 24.

Main menu

The main control console menu has options that provide access to the management features of the control console.

1- Device Manager (equivalent to Device User in the Web interface)

2- Network

3- System

4- Logout

Note: When you log on as Device Manager, you do not have access to the Network or System menus.

Device Manager option

This option accesses the Device Manager menu, which displays information about the unit and the group. Select the components you want to manage. For example:

1- View Active Alarms

2- Cooling Group

3- Cooling Unit

InRow RC/RD/RP (600 mm) User’s Guide

11

Image 19
Contents User’s Guide Page Contents Web Interface Administration Security Administration Notification Verifying Upgrades and Updates Page Product Description Features of the InRow RC/RD/RP 600 mm cooling unitInitial setup IntroductionAccess priority for logging on Internal Management FeaturesOverview Types of user accounts How to Recover from a Lost Password Display Interface LEDs Watchdog FeaturesRemote access to the control console How to Log OnControl Console Local access to the control console Example main screen Main ScreenInformation and status fields Main screen status fields Device Manager option Control Console MenusMenu structure Main menuNetwork option Control Administrator and Device Manager accessSystem option Supported Web browsers Web InterfaceURL address formats Error Message Browser Cause of the Error Common browser error messages at log onHelp SummaryNavigation tabs Quick statusSelect a tab to perform a task InRow RC/RD/RP 600 mm User’s Guide Group Alarm statusCooling Unit Operation HomeSetpoints ConfigurationDehumid Deadband 2.0-10.0% Detailed status UnitIdentification Compressor drive status ACRD500 and ACRP100 cooling unitsRun hours Thresholds Service intervalsAir Filter-18 weeks Humidifier-26 weeks Condensate Pump-52 weeksConfiguration Reverse lookup LogsEvents LogGraphing DataInterval Rotation Hours specified as Delay hours between UploadsParameter Description Syslog Setting DefinitionServers Settings Test How to use FTP or SCP to retrieve the log files Queries Modbus requests and Snmp GETs Permission levels Administration SecuritySetting user access Local UsersRemote Users AuthenticationInRow RC/RD/RP 600 mm User’s Guide Summary of the configuration procedure Configuring the Radius ServerConfiguring a Radius server on UNIX, with shadow passwords Inactivity TimeoutSupported Radius servers Setting Administration NetworkTCP/IP and communication settings TCP/IP settingsDhcp Configuration page1Dhcp response options Boot mode transition. Tag 2, Len 1, Data 1/2APC cookie. Tag 1, Len 4, Data 1APC Port speed Query Type Selected Query Question to Use DNS AdminstrationNetworkDNSserversWeb EnabledOption Description Status On this link to view the certificate’s contentsAES ConsoleIs loaded Snmp Option Description Related Topics FTP serverTypes of notification Administration NotificationConfiguring event actions Event ActionsInRow RC/RD/RP 600 mm User’s Guide InRow RC/RD/RP 600 mm User’s Guide Mail notification Active, Automatic, Direct NotificationSmtp Setting DescriptionSnmp traps Information about the Cooling Unit Administration General OptionsDate & time Action Definition User configuration file iniReset the interface Unit preferenceQuick links Serial ModbusAbout Installation APC Device IP Configuration WizardCapabilities, Requirements, and Installation Use the Wizard to configure basic TCP/IP settingsSelect Remotely over the network, and click Next Configure the basic TCP/IP settings remotelyUse the Wizard Launch the WizardSelect Locally through the serial port, and click Next Configure or reconfigure the TCP/IP settings locallyRetrieving and Exporting the .ini File How to Export Configuration SettingsSummary of the procedure Contents of the .ini fileDetailed procedures Exporting the file to multiple cooling units. T Event text Description Upload Event and Error MessagesEvent and its error messages Errors generated by overridden valuesFirmware files How to Upgrade FirmwareFile Transfers Benefits of upgrading firmwareFirmware file transfer methods Ftp put apchw03aosxxx.bin Use FTP or SCP to upgrade one cooling unit\cd\apc Ftp open 150.250.6.10Use Xmodem to upgrade one cooling unit Upgrade multiple cooling unitsInRow RC/RD/RP 600 mm User’s Guide Last transfer result codes Verifying Upgrades and UpdatesCode Description Page Page 2009 990-2937A
Related manuals
Manual 50 pages 52.8 Kb

ACRD501, ACRC501, ACRD500, ACRC500, ACRP500 specifications

The APC ACRP series, consisting of models ACRP100, ACRP101, ACRP102, ACRP501, and ACRP500, represents a significant innovation in power distribution and protection. These compact, reliable, and efficient solutions are designed specifically for critical applications in data centers, industrial environments, and commercial facilities.

The ACRP100 is the entry-level model, providing essential features for basic power monitoring and control. It incorporates advanced metering capabilities, enabling users to monitor voltage, current, and power consumption in real-time. The ACRP100's user-friendly interface allows for easy navigation, making it an ideal choice for small to medium-sized installations that require fundamental power management.

Stepping up, the ACRP101 enhances functionality with added remote monitoring capabilities. This model introduces smart connectivity features, allowing users to access critical data from anywhere through a secure mobile application or web-based platform. With its ability to integrate seamlessly with other APC systems, the ACRP101 is tailored for environments seeking improved operational visibility and proactive maintenance.

The ACRP102 takes a further leap by integrating advanced predictive analytics. This model uses machine learning algorithms to analyze data trends, predicting potential failures before they occur. By minimizing downtime and optimizing maintenance schedules, the ACRP102 becomes a vital tool for organizations focused on reliability and efficiency.

In the higher-end range, the ACRP501 offers robust power management features, including enhanced surge protection and redundancy capabilities. This model is ideal for mission-critical operations where every second counts. It supports a wide range of input voltages and can manage multiple power sources concurrently, ensuring uninterrupted power supply in fluctuating conditions.

Lastly, the ACRP500 combines all the leading features of the series, focusing on scalability and flexibility. This model is engineered to adapt to evolving infrastructure needs, supporting modular configurations that can grow with the organization. Its extensive reporting functions and customizable dashboards provide clear insights into power usage and performance metrics, empowering facility managers to make informed decisions.

In summary, the APC ACRP series provides a comprehensive suite of solutions for power management, tailored to meet diverse operational needs. From basic monitoring with the ACRP100 to the predictive capabilities of the ACRP102 and the advanced functionalities of the ACRP500, these models collectively offer enhanced reliability, efficiency, and scalability while ensuring optimal protection for critical applications.