APC ACRP100, ACRP501, ACRP500, ACRP101, ACRD500, ACRD501, ACRC501, ACRC500 manual About

Page 66

About

The hardware information is especially useful to APC Customer Support in helping to troubleshoot problems with your cooling unit. The serial number and MAC address accessible through the About menu option are also available on the cooling unit itself. Management Uptime shows the time that has elapsed since the last reset or reboot.

Firmware information, listed under Application Module and APC OS (AOS), indicates the name, firmware version number, and the date and time each firmware module was created. This information may also be useful in troubleshooting and enables you to determine quickly if updated firmware is available to download from the APC Web site.

Hardware Factory

Model Number

Serial Number

Hardware Revision

Manufacture Date

MAC Address

Management Uptime

Application Module

Name

Version

Date

Time

APC OS (AOS)

Name

Version

Date

Time

58

InRow RC/RD/RP (600 mm) User’s Guide

Image 66 Contents
User’s Guide Page Contents Web Interface Administration Security Administration Notification Verifying Upgrades and Updates Page Introduction Features of the InRow RC/RD/RP 600 mm cooling unitInitial setup Product DescriptionInternal Management Features Access priority for logging onOverview Types of user accounts How to Recover from a Lost Password Watchdog Features Display Interface LEDsHow to Log On Remote access to the control consoleControl Console Local access to the control console Main Screen Example main screenInformation and status fields Main screen status fields Main menu Control Console MenusMenu structure Device Manager optionControl Administrator and Device Manager access Network optionSystem option Web Interface Supported Web browsersURL address formats Common browser error messages at log on Error Message Browser Cause of the ErrorQuick status SummaryNavigation tabs HelpSelect a tab to perform a task InRow RC/RD/RP 600 mm User’s Guide Home Alarm statusCooling Unit Operation GroupConfiguration SetpointsDehumid Deadband 2.0-10.0% Unit Detailed statusCompressor drive status ACRD500 and ACRP100 cooling units IdentificationRun hours Condensate Pump-52 weeks Service intervalsAir Filter-18 weeks Humidifier-26 weeks ThresholdsConfiguration Log LogsEvents Reverse lookupData GraphingInterval Hours specified as Delay hours between Uploads RotationParameter Description Setting Definition SyslogServers Settings Test How to use FTP or SCP to retrieve the log files Queries Modbus requests and Snmp GETs Local Users Administration SecuritySetting user access Permission levelsAuthentication Remote UsersInRow RC/RD/RP 600 mm User’s Guide Configuring the Radius Server Summary of the configuration procedureInactivity Timeout Configuring a Radius server on UNIX, with shadow passwordsSupported Radius servers TCP/IP settings Administration NetworkTCP/IP and communication settings SettingConfiguration page1 DhcpBoot mode transition. Tag 2, Len 1, Data 1/2 Dhcp response optionsAPC cookie. Tag 1, Len 4, Data 1APC Port speed DNS AdminstrationNetworkDNSservers Query Type Selected Query Question to UseEnabled WebOption Description On this link to view the certificate’s contents StatusConsole AESIs loaded Snmp Option Description FTP server Related TopicsEvent Actions Administration NotificationConfiguring event actions Types of notificationInRow RC/RD/RP 600 mm User’s Guide InRow RC/RD/RP 600 mm User’s Guide Active, Automatic, Direct Notification Mail notificationSetting Description SmtpSnmp traps Administration General Options Information about the Cooling UnitDate & time Unit preference User configuration file iniReset the interface Action DefinitionSerial Modbus Quick linksAbout Use the Wizard to configure basic TCP/IP settings APC Device IP Configuration WizardCapabilities, Requirements, and Installation InstallationLaunch the Wizard Configure the basic TCP/IP settings remotelyUse the Wizard Select Remotely over the network, and click NextConfigure or reconfigure the TCP/IP settings locally Select Locally through the serial port, and click NextContents of the .ini file How to Export Configuration SettingsSummary of the procedure Retrieving and Exporting the .ini FileDetailed procedures Exporting the file to multiple cooling units. T Errors generated by overridden values Upload Event and Error MessagesEvent and its error messages Event text DescriptionBenefits of upgrading firmware How to Upgrade FirmwareFile Transfers Firmware filesFirmware file transfer methods Ftp open 150.250.6.10 Use FTP or SCP to upgrade one cooling unit\cd\apc Ftp put apchw03aosxxx.binUpgrade multiple cooling units Use Xmodem to upgrade one cooling unitInRow RC/RD/RP 600 mm User’s Guide Verifying Upgrades and Updates Last transfer result codesCode Description Page Page 990-2937A 2009
Related manuals
Manual 50 pages 52.8 Kb