APC ACRP501, ACRP500, ACRP100, ACRP101, ACRD500 manual Exporting the file to multiple cooling units. T

Page 72

Transferring the file to a single cooling unit. To transfer the .ini file to one other cooling unit, do either of the following:

From the Web interface of the receiving cooling unit, select the Administration tab, General on the top menu bar, and User Config File on the left navigation menu. Enter the full path of the .ini file to transfer or use the Browse button to identify the location of the .ini file.

Use any of the file transfer protocols supported by cooling units (including FTP, FTP Client, SCP, and TFTP). The following example uses FTP:

a.From the folder containing the customized .ini file and its copy, use FTP to log in to the cooling unit to which you are exporting the .ini file. For example:

ftp> open 158.165.4.135

b.Export the copy of the customized .ini file. The receiving cooling unit accepts any file name that has the .ini suffix, is no more than 64 characters in length, and is exported to its root directory.

ftp> put filename.ini

Exporting the file to multiple cooling units. T

Use FTP or SCP, but write a script that incorporates and repeats the steps used for exporting the file to a single cooling unit.

Use a batch processing file and the APC .ini file utility.

To create the batch file and use the utility, see Release Notes: ini File Utility, version 1.0 on the Utility CD.

64

InRow RC/RD/RP (600 mm) User’s Guide

Image 72
Contents User’s Guide Page Contents Web Interface Administration Security Administration Notification Verifying Upgrades and Updates Page Features of the InRow RC/RD/RP 600 mm cooling unit Initial setupIntroduction Product DescriptionInternal Management Features Access priority for logging onOverview Types of user accounts How to Recover from a Lost Password Watchdog Features Display Interface LEDsHow to Log On Remote access to the control consoleControl Console Local access to the control console Main Screen Example main screenInformation and status fields Main screen status fields Control Console Menus Menu structureMain menu Device Manager optionControl Administrator and Device Manager access Network optionSystem option Web Interface Supported Web browsersURL address formats Common browser error messages at log on Error Message Browser Cause of the ErrorSummary Navigation tabsQuick status HelpSelect a tab to perform a task InRow RC/RD/RP 600 mm User’s Guide Alarm status Cooling Unit OperationHome GroupConfiguration SetpointsDehumid Deadband 2.0-10.0% Unit Detailed statusCompressor drive status ACRD500 and ACRP100 cooling units IdentificationRun hours Service intervals Air Filter-18 weeks Humidifier-26 weeksCondensate Pump-52 weeks ThresholdsConfiguration Logs EventsLog Reverse lookupData GraphingInterval Hours specified as Delay hours between Uploads RotationParameter Description Setting Definition SyslogServers Settings Test How to use FTP or SCP to retrieve the log files Queries Modbus requests and Snmp GETs Administration Security Setting user accessLocal Users Permission levelsAuthentication Remote UsersInRow RC/RD/RP 600 mm User’s Guide Configuring the Radius Server Summary of the configuration procedureInactivity Timeout Configuring a Radius server on UNIX, with shadow passwordsSupported Radius servers Administration Network TCP/IP and communication settingsTCP/IP settings SettingConfiguration page1 DhcpBoot mode transition. Tag 2, Len 1, Data 1/2 Dhcp response optionsAPC cookie. Tag 1, Len 4, Data 1APC Port speed DNS AdminstrationNetworkDNSservers Query Type Selected Query Question to UseEnabled WebOption Description On this link to view the certificate’s contents StatusConsole AESIs loaded Snmp Option Description FTP server Related TopicsAdministration Notification Configuring event actionsEvent Actions Types of notificationInRow RC/RD/RP 600 mm User’s Guide InRow RC/RD/RP 600 mm User’s Guide Active, Automatic, Direct Notification Mail notificationSetting Description SmtpSnmp traps Administration General Options Information about the Cooling UnitDate & time User configuration file ini Reset the interfaceUnit preference Action DefinitionSerial Modbus Quick linksAbout APC Device IP Configuration Wizard Capabilities, Requirements, and InstallationUse the Wizard to configure basic TCP/IP settings InstallationConfigure the basic TCP/IP settings remotely Use the WizardLaunch the Wizard Select Remotely over the network, and click NextConfigure or reconfigure the TCP/IP settings locally Select Locally through the serial port, and click NextHow to Export Configuration Settings Summary of the procedureContents of the .ini file Retrieving and Exporting the .ini FileDetailed procedures Exporting the file to multiple cooling units. T Upload Event and Error Messages Event and its error messagesErrors generated by overridden values Event text DescriptionHow to Upgrade Firmware File TransfersBenefits of upgrading firmware Firmware filesFirmware file transfer methods Use FTP or SCP to upgrade one cooling unit \cd\apcFtp open 150.250.6.10 Ftp put apchw03aosxxx.binUpgrade multiple cooling units Use Xmodem to upgrade one cooling unitInRow RC/RD/RP 600 mm User’s Guide Verifying Upgrades and Updates Last transfer result codesCode Description Page Page 990-2937A 2009
Related manuals
Manual 50 pages 52.8 Kb

ACRD501, ACRC501, ACRD500, ACRC500, ACRP500 specifications

The APC ACRP series, consisting of models ACRP100, ACRP101, ACRP102, ACRP501, and ACRP500, represents a significant innovation in power distribution and protection. These compact, reliable, and efficient solutions are designed specifically for critical applications in data centers, industrial environments, and commercial facilities.

The ACRP100 is the entry-level model, providing essential features for basic power monitoring and control. It incorporates advanced metering capabilities, enabling users to monitor voltage, current, and power consumption in real-time. The ACRP100's user-friendly interface allows for easy navigation, making it an ideal choice for small to medium-sized installations that require fundamental power management.

Stepping up, the ACRP101 enhances functionality with added remote monitoring capabilities. This model introduces smart connectivity features, allowing users to access critical data from anywhere through a secure mobile application or web-based platform. With its ability to integrate seamlessly with other APC systems, the ACRP101 is tailored for environments seeking improved operational visibility and proactive maintenance.

The ACRP102 takes a further leap by integrating advanced predictive analytics. This model uses machine learning algorithms to analyze data trends, predicting potential failures before they occur. By minimizing downtime and optimizing maintenance schedules, the ACRP102 becomes a vital tool for organizations focused on reliability and efficiency.

In the higher-end range, the ACRP501 offers robust power management features, including enhanced surge protection and redundancy capabilities. This model is ideal for mission-critical operations where every second counts. It supports a wide range of input voltages and can manage multiple power sources concurrently, ensuring uninterrupted power supply in fluctuating conditions.

Lastly, the ACRP500 combines all the leading features of the series, focusing on scalability and flexibility. This model is engineered to adapt to evolving infrastructure needs, supporting modular configurations that can grow with the organization. Its extensive reporting functions and customizable dashboards provide clear insights into power usage and performance metrics, empowering facility managers to make informed decisions.

In summary, the APC ACRP series provides a comprehensive suite of solutions for power management, tailored to meet diverse operational needs. From basic monitoring with the ACRP100 to the predictive capabilities of the ACRP102 and the advanced functionalities of the ACRP500, these models collectively offer enhanced reliability, efficiency, and scalability while ensuring optimal protection for critical applications.