Table of Contents
Specifications | pg. 1 |
Important Safety Instructions / FCC Notice | pg. 2 |
Key Features and Functions | pg. 3 |
Front and Back Panel Descriptions | pg. 4 |
Installing Your MX5102 / UPS Operation | pg. 5 |
Advanced Operation | pg. 6 |
Warranty Information | pg. 7 |
Before you begin unpacking inspect the MX5102 upon receipt.
In addition to this manual the box should contain the following:
1. UPS Unit | 2. Rack Mounting Kit | 3. Coaxial Cables | 4. | 5. |
MX5102 Specifications
AC Power
Line Voltage | 120V, 60Hz |
Total Current Capacity | 12 A |
Energy Dissipation | 1800 Joules |
Catastrophic Surge Circuit | Yes |
Thermal Fusing | Yes |
Overvoltage Shutoff, fast rise | 150 ± 5 V |
Overvoltage Shutoff, slow rise | 132 ± 5 V |
Undervoltage Shutoff | 90 ± 5 V |
EMI/RFI Noise Filtration |
|
Bank 1 EMI Filtration | 66dB Max, |
Bank 2 EMI Filtration | 66dB Max, |
UPS Output |
|
Voltage | 120 ± 5% Simulated Sine Wave |
Frequency | 60 Hz ± 1% |
UPS Output Capacity | 600VA/360W @ 0.6pf |
UPS Backup Time | 3 minutes at full load |
Transfer Time | < 10ms |
Specifications are subject to changes due to product upgrades and improvements.
DC Trigger Input
Jacks | 3.5mm (1/8”) mono |
Voltage and Polarity | 3 - 18V DC, bidirectional |
Current Requirement | 4.6 mA @3V, 58 mA @18V |
LAN Circuits |
|
Clamping Level | 50V |
Jacks | |
Wires Protected | |
Telephone Circuit |
|
Yes | |
Clamping Level | 275V |
Suppression Modes | Metallic & Longitudinal |
Jacks | |
Wires Protected | |
Cable and Satellite Circuits |
|
HD 1080 i/p Ready | Yes |
Yes | |
Shielded | Yes |
Clamping Level | 75V |
Frequency Range | 0MHz - 2.2 GHz |
Insertion Loss | < 0.5 dB |
Connections | Female “F”, Gold Plated |