COMMAND QUICK REFERENCE
This section lists all software commands of the printer. For more information please refer to the Programmer’s Manual.
Command Set for PPLA
The following commands are for Printer Programming Language A.
Note: In this quick reference all variable data is represented in Italics.
System Setting Commands
These commands will cause the related parameters to be saved in the
Command | Description | Parameter | Factory default |
|
|
|
|
<STX>KI4n | Media empty check | n : ‘0’ - disable, | Enabled |
|
| ‘1’ - enable. |
|
<STX>KI7n | Set ribbon mode | n : ‘0’ – DT, | TT with ribbon |
|
| ‘1’ – TT. | (for FM4402) |
|
|
| |
|
|
|
|
<STX>KI8n | Set baud rate | n : ‘0’ – 9600, | 9600 baud. |
|
| ‘1’ – 600, | (for FM4402) |
|
| ‘2’ – 2400, | |
|
|
| |
|
| ‘3’ – 19200, |
|
|
| ‘4’ – 4800, |
|
|
| ‘5’ – 38400, |
|
|
| ‘6’ – 1200, |
|
|
| ‘7’ – 9600. |
|
<STX>KI;n | Control Code types | n : '0' - selects standard control | For FM4402 |
|
| codes. |
|
|
| '1' - Select alternate control |
|
|
| codes |
|
<STX>KXnnnn | Set continuous label | nnnn : a |
|
| length |
|
|
|
|
|
|
<STX>KI<m | Set symbol set for ASD | m : ‘0’ - USASCII, | 0 for USASCII |
| smooth font set | ‘1’ - United Kingdom, |
|
|
| ‘2’ - Spanish, |
|
|
| ‘3’ - Swedish, |
|
|
| ‘4’ - French, |
|
|
| ‘5’ - German, |
|
|
| ‘6’ - Italian, |
|
|
| ‘7’ - Danish/Norwegian. |
|