Toshiba 1000 Series manual Introduction, System Description

Page 23

1. Introduction

The information provided in this manual covers single phase 1000 – 1200 VA uninterruptible power systems. Included in this manual is information on the installation, operation, safety precautions, shipping, and storage of the equipment.

Installation must be carried out in accordance with this manual. Electrical installations must also follow local legislation and regulations. Only qualified personnel should install this equipment. Failure to comply with the warnings and precautions could prove to be fatal.

2. System Description

The purpose of the UPS is to protect sensitive systems from poor quality utility power, complete loss of power, or other associated problems. System types include computers, workstations, process control systems, telecommunications systems, sales terminals, or other critical instrumentation.

Electrical interference may occur causing problems in AC power. Interference may come from lightning, the power company, radio transmissions, or motors. Normal operation of sensitive electrical equipment requires protection against power outages, low or high voltage levels, frequency variations, differential and common-mode noises, and transients.

In order to prevent power line problems from reaching critical systems and causing damage to software, hardware or causing equipment to malfunction, the UPS helps by maintaining a constant voltage, isolating critical load output, and cleaning the utility AC power.

1

Image 23
Contents Page Important Notice Uninterruptible Power Supply Table of Contents Manual’s Purpose and Scope Page ICES-003 EMC StatementsFCC Part Declaration of Conformity Request Safety Alert Symbol / Signal Words General Safety InstructionsPage Special Symbols Qualified Personnel shall Important Safety InstructionsQualified Personnel only XII Important Safety Instructions contd XIV LA Sécurité Conserver CES Instructions Instructions Importantes ConcernantInspection/Storage/Disposal Disposal Storage MaintenanceInstallation Precautions Conductor Routing and Grounding Operating Precautions XXI System Description IntroductionGeneral Description Block diagramPage Diagnostic Tests Free Run ModeSystem Configuration Storage Environment InstallationVertical and Wall-mounted Installations with Accessories Rack-mounted Installation with Accessories Stacked UPS Installation with accessories Rear Panel Views 1000VA 1200VA Tower Rear Panel 1000VA Rack mount 1U Rear Panel 1000VA Rack mount 2U Rear Panel Connection to main supply and loads 1000 1200 VA Example of Installation of Plug & Play products Settings Options Default Remarks Front Panel SettingsBattery Test TEST? RS-232 Standard Interface Port Computer and Alarm ConnectionsLoad Segments EPO Port emergency power offUSB Port Network Transient ProtectorButton Operation User’s Guide to OperationsUPS Startup and Shutdown Starting the UPS Shutting Down the UPSON-LINE Control Panel functionsLCD Message Description Normal DisplayUPS Meters Display UPS Configurations Interpreting UPS Messages Audible AlarmsSilencing an Alarm UPS Manual TestTroubleshooting Maintenance Output Technical SpecificationsPower Range 1000-1200 VA LV General InputEnvironmental Power Range1000 VA 19 Rack-mount model, LV, 1U & 2U GeneralPower Range 1000-1200 VA HV General Standard Power Range 1000 VA 19 Rack-mount model, HV, 1U & 2U GeneralRack-mount HV Model Tower HV ModelRack-mount LV Model Tower LV ModelUninterruptible Power SUPPLIES-UPS Warranty InformationLimitations and Exclusions Page Respective warranty period will warranty work be performed Procedure for Defective Product Screening and DispositionModifications