Toshiba 1000 Series manual User’s Guide to Operations, UPS Startup and Shutdown Starting the UPS

Page 42

5. User’s Guide to Operations

Normal ongoing UPS operation requires little or no user input. Startup and shutdown requirements of the user are discussed in this section.

5.2UPS Startup and Shutdown Starting the UPS

Ensure that installation is correct and that the input power cable is connected to a properly grounded outlet.

Start the UPS by pressing the On/Off button on the front panel.

The UPS will start the inspection of internal functions, main synchronization, and inverter startup. A successful completion allows for output power via the outlets.

During the startup inspection the LCD will display Ready On. The LED will light up when output power has started and the LCD display will show Line Mode.

Switch on the load.

Shutting Down the UPS

Shut off and disconnect the load.

Press and hold the UPS On/Off button for five seconds. The alarm will sound and the UPS will shut down.

The LCD will momentarily display UPS OFF.

Note: In emergency situations the EPO should be used.

5.3 Button Operation

1. ” is the Load ON/OFF button.

(a)Press and hold the Load ON/OFF button for at least 3 seconds to turn on the UPS.

(b)While the UPS is operating, press and hold the Load ON/OFF button for at least 3 seconds to turn off the UPS.

20

Image 42
Contents Page Important Notice Uninterruptible Power Supply Table of Contents Manual’s Purpose and Scope Page EMC Statements FCC PartICES-003 Declaration of Conformity Request General Safety Instructions Safety Alert Symbol / Signal WordsPage Special Symbols Important Safety Instructions Qualified Personnel onlyQualified Personnel shall XII Important Safety Instructions contd XIV Instructions Importantes Concernant LA Sécurité Conserver CES InstructionsInspection/Storage/Disposal Storage Maintenance DisposalInstallation Precautions Conductor Routing and Grounding Operating Precautions XXI Introduction System DescriptionBlock diagram General DescriptionPage Free Run Mode Diagnostic TestsSystem Configuration Storage Installation EnvironmentVertical and Wall-mounted Installations with Accessories Rack-mounted Installation with Accessories Stacked UPS Installation with accessories Rear Panel Views 1000VA 1200VA Tower Rear Panel 1000VA Rack mount 1U Rear Panel 1000VA Rack mount 2U Rear Panel Connection to main supply and loads 1000 1200 VA Example of Installation of Plug & Play products Front Panel Settings Settings Options Default RemarksBattery Test TEST? Computer and Alarm Connections RS-232 Standard Interface PortNetwork Transient Protector EPO Port emergency power offUSB Port Load SegmentsShutting Down the UPS User’s Guide to OperationsUPS Startup and Shutdown Starting the UPS Button OperationControl Panel functions ON-LINENormal Display UPS Meters DisplayLCD Message Description UPS Configurations UPS Manual Test Audible AlarmsSilencing an Alarm Interpreting UPS MessagesTroubleshooting Maintenance Input Technical SpecificationsPower Range 1000-1200 VA LV General OutputPower Range1000 VA 19 Rack-mount model, LV, 1U & 2U General EnvironmentalPower Range 1000-1200 VA HV General Power Range 1000 VA 19 Rack-mount model, HV, 1U & 2U General StandardTower HV Model Rack-mount HV ModelTower LV Model Rack-mount LV ModelWarranty Information Uninterruptible Power SUPPLIES-UPSLimitations and Exclusions Page Procedure for Defective Product Screening and Disposition Respective warranty period will warranty work be performedModifications