Toshiba 1000 Series manual General Description, Block diagram

Page 24

2.1 General Description

As a double conversion on-line UPS, it is able to supply uninterrupted, clean single- phase power to your critical systems while keeping batteries charged continuously, even if the utility power fails.

Other features of the UPS includes

Auto-Restart and Cold Start features

Programmable Load Shed Receptacle

Intelligent Charger with Rapid Charge in only 3.5 hours to 90%

Wide Input Voltage Window

Wide Input Frequency Window for Complete Generator Compatibility

Input Power Factor greater than 0.97

Output Power Factor 0.70

Multiple Languages LCD Display

Free Run Mode - See detail explanation on page 4

Diagnostic Tests - See detail explanation on page 4

Optional Network Interface Card

Optional Environmental Monitoring Device

In the event that a power failure lasts longer than the UPS backup time, the UPS will shut down. Upon power restoration, the UPS will restart automatically, which includes output power being restored to the load and the start of battery recharge.

See following figure for systemic applicable of the UPS system.

Figure 1. Block diagram

2

Image 24
Contents Page Important Notice Uninterruptible Power Supply Table of Contents Manual’s Purpose and Scope Page EMC Statements FCC PartICES-003 Declaration of Conformity Request General Safety Instructions Safety Alert Symbol / Signal WordsPage Special Symbols Important Safety Instructions Qualified Personnel onlyQualified Personnel shall XII Important Safety Instructions contd XIV Instructions Importantes Concernant LA Sécurité Conserver CES InstructionsInspection/Storage/Disposal Storage Maintenance DisposalInstallation Precautions Conductor Routing and Grounding Operating Precautions XXI Introduction System DescriptionBlock diagram General DescriptionPage Free Run Mode Diagnostic TestsSystem Configuration Storage Installation EnvironmentVertical and Wall-mounted Installations with Accessories Rack-mounted Installation with Accessories Stacked UPS Installation with accessories Rear Panel Views 1000VA 1200VA Tower Rear Panel 1000VA Rack mount 1U Rear Panel 1000VA Rack mount 2U Rear Panel Connection to main supply and loads 1000 1200 VA Example of Installation of Plug & Play products Front Panel Settings Settings Options Default RemarksBattery Test TEST? Computer and Alarm Connections RS-232 Standard Interface PortEPO Port emergency power off USB PortNetwork Transient Protector Load SegmentsUser’s Guide to Operations UPS Startup and Shutdown Starting the UPSShutting Down the UPS Button OperationControl Panel functions ON-LINENormal Display UPS Meters DisplayLCD Message Description UPS Configurations Audible Alarms Silencing an AlarmUPS Manual Test Interpreting UPS MessagesTroubleshooting Maintenance Technical Specifications Power Range 1000-1200 VA LV GeneralInput OutputPower Range1000 VA 19 Rack-mount model, LV, 1U & 2U General EnvironmentalPower Range 1000-1200 VA HV General Power Range 1000 VA 19 Rack-mount model, HV, 1U & 2U General StandardTower HV Model Rack-mount HV ModelTower LV Model Rack-mount LV ModelWarranty Information Uninterruptible Power SUPPLIES-UPSLimitations and Exclusions Page Procedure for Defective Product Screening and Disposition Respective warranty period will warranty work be performedModifications