APC 6000 user manual General definitions Signaling field, Tables of measured data, Current fields

Page 29

General definitions

Signaling field

(same for all cubicle types)

System information (continued)

object

0

1

switch

open

closed

 

 

 

unit

off

on

 

 

 

fault

no fault

fault

 

 

 

control device

not activated

activated

 

 

 

signaling

units

data

 

JBUS address

 

 

 

 

hex. word

synchronisation counter

 

 

 

0

(MSB)

 

 

 

 

synchronisation counter

ms

0

4294967295

1

(LSB)

 

 

 

 

 

 

 

 

 

binary times

 

N/A

 

2

binary times

 

N/A

 

3

binary times

 

N/A

 

4

binary times

 

N/A

 

5

manufacturer's ID

without

1

 

MSB 6

model ID (MSB)

without

102

 

LSB 6

model ID (LSB)

without

54380

 

7

configuration 1

without

N/A

 

MSB 8

 

 

inverter type,

 

LSB 8

 

 

same as 200

 

 

 

 

 

 

 

configuration 2

without

hardware version

 

MSB 9

 

 

software version

 

LSB 9

 

 

 

 

 

not used

 

 

 

A

not used

 

 

 

B

state of equipment

without

same as 4E

 

C

state of processing

without

same as 4C

 

D

not used

 

 

 

E

not used

 

 

 

F

Tables of measured data

Current fields

measured current

units

JBUS address

type

 

 

Legend:

 

 

 

hex. word

unitary

parallel

Static Switch

 

 

 

 

 

 

 

yes: available in this cubicle;

I1

(I phase 1) Mains 1

A

100

yes

yes

 

 

 

 

 

 

 

 

I2

(I phase 2) Mains 1

A

101

yes

yes

 

bat: available in this cubicle if

 

 

 

 

 

 

 

 

I3

(I phase 3) Mains 1

A

102

yes

yes

 

battery installed;

 

 

 

 

 

 

 

 

I1

(I phase 1) inverter

A

106

yes

yes

 

no entry: not available.

 

 

 

 

 

 

 

 

I2

(I phase 2) inverter

A

107

yes

yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I3

(I phase 3) inverter

A

108

yes

yes

 

 

 

 

 

 

 

 

 

 

 

 

I1

(I phase 1) Mains 2

A

109

yes

 

yes

 

 

 

 

 

 

 

 

 

 

 

I2

(I phase 2) Mains 2

A

10A

yes

 

yes

 

 

 

 

 

 

 

 

 

 

 

I3

(I phase 3) Mains 2

A

10B

yes

 

yes

 

 

 

 

 

 

 

 

 

 

 

I1

(I phase 1) load

A

10C

yes

yes

yes

 

 

 

 

 

 

 

 

 

 

 

I2

(I phase 2) load

A

10D

yes

yes

yes

 

 

 

 

 

 

 

 

 

 

 

I3

(I phase 3) load

A

10E

yes

yes

yes

 

 

 

 

 

 

 

 

 

 

I battery

A

115

bat

bat

 

 

 

 

 

 

 

 

 

 

 

% load

-

120

yes

yes

yes

 

 

 

 

 

 

 

 

 

 

% peak load (Ph1)

-

121

yes

yes

yes

 

 

 

 

 

 

 

 

 

 

% peak load (Ph2)

-

122

yes

yes

yes

 

 

 

 

 

 

 

 

 

 

% peak load (Ph3)

-

123

yes

yes

yes

6739389EN/FB - Page 29

Image 29
Contents GTC link communication interface Mgetm GalaxyTM2 6739389EN/FB Contents Introduction PresentationACQ module COM moduleInterface Communication settingsJbus protocol Description of request and response frames PrincipleSynchronizing data exchanges Checking received messages on the slave side Function 1 and 2 read N bits FunctionsFunction 5 writing a bit Function 3 and 4 read N wordsFunction 6 writing a word Function 8 reading error diagnosis countersFunction 15 writing n consecutive bits Function 11 reading event countersMSB LSB MSB LSB MSB Function 16 writing n consecutive wordsCRC 16 algorithm Example of CRC computation Table of Most Significant Bytes for CRC16 Computation Example of CRC 16 computation in C using table lookupJbus protocol Unitary UPS UPS theory of operationUPS without Mains Parallel connected UPS with Static Switch cubicleOperation without battery Operation with battery Measured quantities Block diagramUnitary UPS Operating modes Normal operation Load on batteryMain status bits UPS operating information Load on Mains Load on bypass Parallel connected UPS Main status bits of system operations Normal operation Load on battery DisconnectedStatic Switch cubicle Normal operation Load on Mains Load on bypass Static SwitchMain indicators of system operations Sample commands List of variable fields Example of read data array commands sent by the terminalSystem information Message formatCurrent fields General definitions Signaling fieldTables of measured data Voltage fields Power fields Frequency fieldsRectifier-charger Battery and adjustments fieldsTables of binary data Connectivity InverterGlobal information Table of control devicesWord address Glossary of information descriptorsInverter stack overload 0=no/1=overload Word address 4C Word address 4AWord address 4E summary Word address 4DWord address C1 C10 call reset 0= not activated / 1=activated