APC 6000 user manual Tables of binary data, Battery and adjustments fields, Rectifier-charger

Page 31

System information (continued)

Battery and adjustments fields

Legend:

no entry: not available;

yes: available in this cubicle;

bat: available in this cubicle if battery installed;

bat/opt: available if option installed.

Inverter type:

0: unitary;

1: parallel without static switch;

2: parallel with static switch;

3: Static Switch cubicle.

Battery installed:

0 = no;

1 = yes.

Sensor installed:

0 = no;

1 = yes.

Tables of binary data

Rectifier-charger

Legend:

no entry: not available;

yes: available in this cubicle;

bat: available in this cubicle if battery installed.

battery measurements

units

JBUS address

type

 

 

 

 

hex. word

unitary

parallel

SS

U battery

V

1C0

yes

yes

 

 

 

 

 

 

 

I battery

A

1C1

bat

bat

 

 

 

 

 

 

 

battery backup time

mn

1C2

bat/opt

bat/opt

 

 

 

 

 

 

 

battery room temperature

°C

1C3

bat/opt

bat/opt

 

 

 

 

 

 

 

battery adjustments

units

JBUS address

type

 

 

 

 

hex. word

unitary

parallel

SS

inverter type

-

200

yes

yes

yes

 

 

 

 

 

 

battery installed

-

201

yes

yes

 

 

 

 

 

 

 

battery temperat. sensor

-

202

yes

yes

 

 

 

 

 

 

 

In (I rated load)

A

208

yes

yes

yes

 

 

 

 

 

 

Pn (P rated load)

kW

209

yes

yes

yes

rectifier-charger

bit meaning

 

JBUS

type

 

 

information

 

 

address

 

 

 

 

 

 

hex.

 

 

 

 

 

bit=0

bit=1

bit

word

unit.

para.

SS

B_Etat_QF1

open

closed

400

40

bat

bat

 

B_Etat_Dech_Bat

not discharging

discharging

401

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_Ubat_Min

not reached

min. volt. fault

402

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_Ubat_Aut

not reached

warning

403

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_Tempe_Ht

normal

outside toleran.

404

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_Res1_Ht

not reached

outside toleran.

405

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_Vent_Bat

no fault

fault

406

 

yes

yes

 

 

 

 

 

 

 

 

 

B_Etat_Cha_Bat

not charging

charging

407

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_Pont

off

on

408

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_Def_Maj_Cha

no fault

fault

409

 

yes

yes

 

 

 

 

 

 

 

 

 

B_Etat_Q1

open

closed

40E

 

yes

yes

 

 

 

 

 

 

 

 

 

B_Etat_Arr_Urg

not activated

activated

411

41

yes

yes

 

 

 

 

 

 

 

 

 

B_Etat_U_Res1

normal

outside toleran.

412

 

yes

yes

 

 

 

 

 

 

 

 

 

B_Etat_F_Res1

normal

outside toleran.

413

 

yes

yes

 

 

 

 

 

 

 

 

 

B_Etat_Arr_Prog

not activated

activated

417

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_Lim_Groupe

not activated

activated

419

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_IBat_Aux

not activated

activated

41A

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_Egal_Bat

not active

active

41B

 

bat

bat

 

 

 

 

 

 

 

 

 

B_Etat_Groupe

not activated

activated

41E

 

yes

yes

 

6739389EN/FB - Page 31

Image 31
Contents GTC link communication interface Mgetm GalaxyTM2 6739389EN/FB Contents COM module PresentationIntroduction ACQ moduleInterface Communication settingsJbus protocol Synchronizing data exchanges PrincipleDescription of request and response frames Checking received messages on the slave side Function 1 and 2 read N bits FunctionsFunction 5 writing a bit Function 3 and 4 read N wordsFunction 6 writing a word Function 8 reading error diagnosis countersFunction 15 writing n consecutive bits Function 11 reading event countersMSB LSB MSB LSB MSB Function 16 writing n consecutive wordsCRC 16 algorithm Example of CRC computation Table of Most Significant Bytes for CRC16 Computation Example of CRC 16 computation in C using table lookupJbus protocol Unitary UPS UPS theory of operationOperation without battery Parallel connected UPS with Static Switch cubicleUPS without Mains Operation with battery Unitary UPS Block diagramMeasured quantities Main status bits UPS operating information Normal operation Load on batteryOperating modes Load on Mains Load on bypass Parallel connected UPS Main status bits of system operations Normal operation Load on battery DisconnectedStatic Switch cubicle Main indicators of system operations Static SwitchNormal operation Load on Mains Load on bypass Message format Example of read data array commands sent by the terminalSample commands List of variable fields System informationTables of measured data General definitions Signaling fieldCurrent fields Voltage fields Power fields Frequency fieldsTables of binary data Battery and adjustments fieldsRectifier-charger Connectivity InverterGlobal information Table of control devicesWord address Glossary of information descriptorsInverter stack overload 0=no/1=overload Word address 4C Word address 4AWord address 4E summary Word address 4DWord address C1 C10 call reset 0= not activated / 1=activated