Anritsu MA24106A, 0701012 manual Status Bar, Using the Power Sensor Display Window

Page 21

Using the Power Sensor

Display Window

3-5 Display Window

The display window contains the following information (see Figure 3-3and Figure 3-4):

Measured Power

Relative Power

Units of Power

Fixed Offset

Offset Table

Figure 3-3.Display Window (Relative Mode with Fixed Offset On)

Figure 3-4.Display Window (Normal mode with Offset Table On)

3-6 Status Bar

The status bar displays the model number, serial number, cal factor frequency, averaging number, and operational status of the sensor (see Figure 3-5).

Figure 3-5. Status Bar

MA24106A UG

3-3

Image 21
Contents True-RMS, 50 MHz to 6 GHz MA24106A USB Power Sensor User GuideUpdates Anritsu Company Software License Agreement Page Table of Contents Table of Contents General Information Preparation for Storage/Shipment Preparation for Storage/ShipmentInstallation Driver InstallationHardware and Software Requirements Anritsu Power Meter Installation Driver InstallationLicense Agreement Installation Driver InstallationSoftware will then install to the selected location Found New Hardware Wizard Select the hardware type Computer, and then click Next Click Have Disk..., and then click Next 14.Found New Hardware Wizard Click Finish to close the wizard Page Graphical User Interface Using the Power SensorButtons Using the Power Sensor ButtonsData Entry Fields Using the Power Sensor Display Window Display WindowStatus Bar Menu Bar Menu Bar Using the Power SensorFile Menu Tools MenuDataLogging Menu Data Logging Menu10. Data Logging Power GraphTime, X-axis 30 minutes 14.Offset Entry Screen Offset Table16. Open Dialog MA24106A UG 17.Offset Table Menu Offset Table Off Status Session RestoreConnecting the DUT Basic Power MeasurementUsing the Power Sensor Making Measurements Making MeasurementsZeroing the Sensor Making Measurements Using the Power SensorCalibrating the Sensor Applying a Calibration Factor Correction±0.20 dB ±0.15 dB ±0.10 dB ±0.05 dB ±0.01 dB DBm Noise Number Averages Needed forTime Varying Signals Error StatesMeasurement Considerations Using the Power Sensor Message Description ResolutionMultitone Signals High Crest Factor Signals peak to average ratioUsing the Power Sensor Measurement Considerations Noise and AveragingSettling Time Uncertainty of a Measurement Using the Power Sensor Uncertainty of a MeasurementUncertainty Adjusted Specification Uncertainty of a Measurement Using the Power SensorUncertainty Example Noise Calculations at 12 dBm 16 mWRemote Operation Commands Summary Command DescriptionRemote Operation Remote Operation Command Details Remote Operation Command DetailsFREQ? Remote Operation Remote Operation Command DetailsHAT Required Equipment Sensor Operational TestsTest Procedure Vswr PretestVswr Pretest Sensor Operational Tests Sensor Operational Tests Calibration Factor Test Calibration Factor TestMA24106A Calibration Factor Test Sensor Operational TestsSensor Operational Tests Linearity Test Linearity TestApply Linearity Test Sensor Operational TestsSensor Operational Tests Linearity Test +20 +15 +10 Adjust per Max Min Delta E11 E12 Measurement Results 2 GHz Measurement Results 6 GHz Beware of destructive pin depth mating connectors Appendix a Connector Care and HandlingAvoid applying excessive power Avoid over torquing connectorsCleaning connectors Connector Care and HandlingUsing the Demo Application Appendix B Sample Visual Basic CodeDemo Application Using the Demo Application Sample Visual Basic Code Sample Visual Basic Code Using the Demo Application Delay routine Appendix C Serial Port Compatibility For Anritsu Power Meter 1.0 OnlyMethod 3-Remapping a Serial Port Method 1-Download Updated SoftwareFigure C-2.System Properties Serial Port CompatibilityFigure C-3.Device Manager Method 3-Remapping a Serial PortFigure C-4.Advanced Settings for COM Port Close all windows that you have opened up to this point Upgrading the Firmware Appendix D Upgrading the FirmwareUpgrading the Firmware Figure D-3.Firmware Upgrade DialogFigure D-5.Open File Dialog Figure D-7 Symbols Symbols to LIndex Index-2 MA24106A UG To SUSB To Z