Anritsu 0701012, MA24106A manual Method 3-Remapping a Serial Port, Figure C-3.Device Manager

Page 60

Method 3–Remapping a Serial Port

Serial Port Compatibility

3.Click the + box next to Ports (COM & LPT) to expand the installed ports list.

Figure C-3.Device Manager

4.Select the port that is assigned to the power sensor. Disconnect and reconnect the sensor and notice the new COM port number that appears. The new port is the current port assignment for the power sensor.

5.Right-click on the new port assigned in step 4 above and select Properties from the pop-up menu to display the properties for that port.

6.Click the Port Settings tab of the properties window.

C-4

MA24106A UG

Image 60
Contents MA24106A USB Power Sensor User Guide True-RMS, 50 MHz to 6 GHzUpdates Anritsu Company Software License Agreement Page Table of Contents Table of Contents General Information Preparation for Storage/Shipment Preparation for Storage/ShipmentInstallation Driver InstallationHardware and Software Requirements Driver Installation Anritsu Power Meter InstallationInstallation Driver Installation License AgreementSoftware will then install to the selected location Found New Hardware Wizard Select the hardware type Computer, and then click Next Click Have Disk..., and then click Next 14.Found New Hardware Wizard Click Finish to close the wizard Page Using the Power Sensor Graphical User InterfaceButtons Using the Power Sensor ButtonsData Entry Fields Using the Power Sensor Display Window Display WindowStatus Bar Menu Bar Using the Power Sensor Menu BarFile Menu Tools MenuData Logging Menu DataLogging MenuPower Graph 10. Data LoggingTime, X-axis 30 minutes Offset Table 14.Offset Entry Screen16. Open Dialog MA24106A UG Session Restore 17.Offset Table Menu Offset Table Off StatusBasic Power Measurement Connecting the DUTUsing the Power Sensor Making Measurements Making MeasurementsMaking Measurements Using the Power Sensor Zeroing the SensorCalibrating the Sensor Applying a Calibration Factor CorrectionNumber Averages Needed for ±0.20 dB ±0.15 dB ±0.10 dB ±0.05 dB ±0.01 dB DBm NoiseError States Time Varying SignalsMeasurement Considerations Using the Power Sensor Message Description ResolutionHigh Crest Factor Signals peak to average ratio Multitone SignalsUsing the Power Sensor Measurement Considerations Noise and AveragingSettling Time Using the Power Sensor Uncertainty of a Measurement Uncertainty of a MeasurementUncertainty of a Measurement Using the Power Sensor Uncertainty Adjusted SpecificationUncertainty Example Noise Calculations at 12 dBm 16 mWRemote Operation Commands Summary Command DescriptionRemote Operation Remote Operation Command Details Remote Operation Command DetailsRemote Operation Remote Operation Command Details FREQ?HAT Sensor Operational Tests Required EquipmentTest Procedure Vswr PretestVswr Pretest Sensor Operational Tests Calibration Factor Test Sensor Operational Tests Calibration Factor TestCalibration Factor Test Sensor Operational Tests MA24106ALinearity Test Sensor Operational Tests Linearity TestLinearity Test Sensor Operational Tests ApplySensor Operational Tests Linearity Test +20 +15 +10 Adjust per Max Min Delta E11 E12 Measurement Results 2 GHz Measurement Results 6 GHz Appendix a Connector Care and Handling Beware of destructive pin depth mating connectorsAvoid over torquing connectors Avoid applying excessive powerCleaning connectors Connector Care and HandlingUsing the Demo Application Appendix B Sample Visual Basic CodeDemo Application Using the Demo Application Sample Visual Basic Code Sample Visual Basic Code Using the Demo Application Delay routine For Anritsu Power Meter 1.0 Only Appendix C Serial Port CompatibilityMethod 1-Download Updated Software Method 3-Remapping a Serial PortSerial Port Compatibility Figure C-2.System PropertiesMethod 3-Remapping a Serial Port Figure C-3.Device ManagerFigure C-4.Advanced Settings for COM Port Close all windows that you have opened up to this point Appendix D Upgrading the Firmware Upgrading the FirmwareFigure D-3.Firmware Upgrade Dialog Upgrading the FirmwareFigure D-5.Open File Dialog Figure D-7 Symbols Symbols to LIndex To S Index-2 MA24106A UGTo Z USB