The MS9520 and MS9540 scanner interfaces terminate to a 10-pin modular jack. The serial # label indicates the interface enabled

1

when the scanner is shipped from the factory.

10

 

 

 

MS9520-47 & MS9540-47

MS9520-9 & MS9520-9 OCIA

 

Keyboard Wedge and Stand-

 

 

 

Alone Keyboard

Pin

Function

 

Function

1

Ground

 

Ground

2

RS-232 Transmit Output

 

RS-232 Transmit Output

3

RS-232 Receive Input

 

RS-232 Receive Input

4

RDATA

 

PC Data

5

RDATA Return

 

PC Clock

6

Clock in

 

KB Clock

7

Clock out

 

PC +5V

8

Clock in Return/Clock out Rtrn

 

KB Data

9

+5VDC

 

+5VDC

10

Shield Ground

 

Shield Ground

 

 

 

MS9520-41 & MS9540-41 RS-232C

 

MS9520-11 & MS9540-11 IBM

 

and Light Pen Emulation

 

468X/469X

 

 

 

 

Pin

Function

 

Function

1

Ground

 

Ground

2

RS-232 Transmit Output

 

RS-232 Transmit Output

3

RS-232 Receive Input

 

RS-232 Receive Input

4

RTS Output

 

RTS Output

5

CTS Input

 

CTS Input

6

DTR Input/LTPN Source

 

DTR Input

7

Reserved

 

IBM B-Transmit

8

LTPN Data

 

IBM A+ Receive

9

+5VDC

 

+5VDC

10

Shield Ground

 

Shield Ground

Options listed are program/cable selections

36

Image 41
Contents Page USA Corporate Headquarters Europe LocationsIii Table of Contents Appendix B Appendix aAppendix C Appendix DVoyager Voyager CodeGate Interface IntroductionVoyager MS9540 CodeGate Single-Line Laser Scanner Scanner and Accessories∙ Installation and User’s Guide Mlpn Quick Start Installing the Scanner to the Host System Disconnecting PowerLink Cables from the Scanner Two Modes of Operation How to Use CodeGate MS9540 OnlyStand Option 1 Self-supported Assembling the StandKit #46-46055 Contains Stand Option 2 Hard-mounted to countertop Scanner Parts Three Beeps On Power Up Audible IndicatorsOne Beep Razzberry ToneThis is a failure indicator. Refer to Failure Modes on Visual Indicators Steady Red, Green off Alternating Flashing of Green and RedFlashing Green and one Razzberry Tone Failure ModesHow does Serial Programming work? Programming ModesHost Scanner Feature Command Ascii Representation Response Abbreviated Ascii Table Upgrading the Flash Rom Firmware Avoid Exposure laser light emitted from this aperture LabelsDistance Depth of FieldScanner Face Width of Scan FieldIR Activation Maintenance Scanner Version Communication Protocols Identifier Applications and ProtocolsTrouble Shooting Guide Symptoms Possible Causes Solution Troubleshooting GuideTroubleshooting Guide Unit scans Receiving data but RS-232 Demonstration Program Operational Appendix a Design SpecificationsLight IBM KBW PEN Appendix B Default SettingsDTS/SIEMENS DTS/NIXDORF NCR F NCR S 46XX Light IBM Parameter Msec to Find Supplement Programmable Msec steps max Rdata Appendix CPin D-type female connector to the PC Function Cable Connector Configurations Standard PowerLink cablePowerLink Cable Pin Female DIN Pin Function Cable Connector ConfigurationPin Male Mini-DIN Pin Function Adapter Cable Pin Male DIN Pin FunctionLimited Warranty Appendix D Warranty and DisclaimerRemarque Appendix E NoticesAttenzione AchtungPatents Appendix FAddendum AddendumCdrh IndexRMA