2.4.4 Multidrop Address Selection

For RS485 half-duplex interface connections, the scanner multidrop address should be set using the rotary switches placed inside the C-BOX 200.

The valid address range is from 00 to 31. This value is read only at power- on; any change at run-time has no effect.

If an invalid value is detected (32-99) the C-BOX cannot communicate with the Multiplexer and the green LED remains off. Furthermore, the SEND command configures the scanner using the previously configured valid scanner address.

TENS

 

UNITS

 

Figure 2.10 - Rotary switches

Installation - 11

Image 20
Contents BOX Installation Manual BOX821000560 Contents Guide to Installation General View Figure aFigure B Safety Precautions Power SupplyViii General Features DescriptionInstallation Package ContentsOpening the Device Opening the C-BOXMechanical Installation Overall dimensionsMounting C-BOX Electrical Connections and Setup System layoutPower Supply Power switch ON/OFF positionsSystem Wiring System cable connectionsRefer to the scanner Installation Manual for details Chassis Grounding Jumper Settings Chassis grounding10 Rotary switches Multidrop Address Selection11 Termination resistance switch 5 RS485 Bus TerminationConnection to a Multiplexer BOX7 OM4000 Jumper Settings 13 OM4000 jumpers14 9-pin male connector Pin connector pinout Name Function 9-PIN Scanner Auxiliary Serial InterfaceScanner Requirements Operating Modes1 GET/SEND Buttons GET SendLED Indicators 15 LED IndicatorsTechnical Features Environmental Features