2.5 9-PIN SCANNER AUXILIARY SERIAL INTERFACE

The scanner auxiliary serial interface available on the internal 9-pin connector can be used either for configuration through WinHost or for data monitoring.

The details of the connector pins are indicated in the following table:

Figure 2.14 - 9-pin male connector

9-pin connector pinout

Pin

Name

 

Function

1

 

 

N.C.

2

RXA

 

Auxiliary RS232

3

TXA

 

Auxiliary RS232

4

 

 

N.C.

5

SGND

 

Signal Ground

6

 

 

N.C.

9

 

 

N.C.

 

 

DS2100 - DS2400

7

CTSA

 

Auxiliary Handshake RS232

8

RTSA

 

Auxiliary Handshake RS232

 

 

 

 

 

 

DS4300 - DS4600

 

 

 

 

7

SGND AUX

 

Auxiliary Signal Ground

8

GND

 

Ground

 

 

 

 

Installation - 15

Image 24
Contents BOX Installation Manual BOX821000560 Contents Guide to Installation General View Figure aFigure B Safety Precautions Power SupplyViii General Features DescriptionInstallation Package ContentsOpening the Device Opening the C-BOXMechanical Installation Overall dimensionsMounting C-BOX Electrical Connections and Setup System layoutPower Supply Power switch ON/OFF positionsSystem Wiring System cable connectionsRefer to the scanner Installation Manual for details Chassis Grounding Jumper Settings Chassis grounding10 Rotary switches Multidrop Address Selection11 Termination resistance switch 5 RS485 Bus TerminationConnection to a Multiplexer BOX7 OM4000 Jumper Settings 13 OM4000 jumpers14 9-pin male connector Pin connector pinout Name Function 9-PIN Scanner Auxiliary Serial InterfaceScanner Requirements Operating Modes1 GET/SEND Buttons GET SendLED Indicators 15 LED IndicatorsTechnical Features Environmental Features