Yamaha Yamaha Robot Controller CC-Link Unit, RCX Series owner manual Connection

Page 21

Chapter 2 Connection

Contents

1.

Confirming the CC-Link compatible module settings

2-1

2.

Setting to the CC-Link system specification controller

2-2

 

2.1

Saving the robot controller data

2-2

 

2.2

Installing the CC-Link compatible module

2-2

 

2.3

Response when starting the robot controller

2-2

3.

Setting the CC-Link compatible module

2-3

 

3.1

Setting the station No

2-3

 

3.2

Setting the communication speed

2-4

4.

Noise measures

2-5

 

4.1

Mounting the ferrite core

2-5

5.

Connecting to the CC-Link system

2-6

 

5.1

Connecting to the cable terminal to the controller

2-6

 

5.2

Testing the line from the master station PLC

2-6

6.

Parameter setting for CC-Link serial I/O board

2-7

 

6.1

Parameter setting for CC-Link serial I/O board

2-8

Image 21
Contents Unit Page Introduction Precautions for design Safety Precautions Always read before starting usePrecautions for wiring Precautions for installationPrecautions for disposal Precautions for starting and maintenanceWarranty description WarrantyMemo Contents Troubleshooting SpecificationsAppendix Outline Memo Features Wiring savingEmulated serialization on parallel DIO PLC MechanismStation No. setting switch MSB 2nd digit Station No. setting switch LSB 1st digitCommunication speed switch BPS CC-Link system cable terminalsA1SHCPU Assignment of CC-Link compatible I/OPLC Outline Outline Memo Connection Memo Operation Confirming the CC-Link compatible module settingsResponse when starting the robot controller Installing the CC-Link compatible moduleProcedure Saving the robot controller dataSetting the station No Setting the CC-Link compatible moduleProcedures Setting the communication speedMounting the ferrite core Noise measuresTesting the line from the master station PLC Connecting to the CC-Link systemParameter Meaning Parameter setting for CC-Link serial I/O boardType Display Meaning Parameter setting for CC-Link serial I/O boardPress the F Edit key Memo Communication Memo When connection to CC-Link system is correctly established State when robot controller power is turned onInitial process for connecting to CC-Link system Initial data processInitial data process master station PLC side Receiving data Communication with master station PLCTransmitting data Direct connection by emulated serialization on parallel DIO Direct connection from SI n to do n Direct connection by emulated serialization on parallel DIODirect connection from SO n to DI n Direct connection by emulated serialization on parallel DReferring to the data from the programming unit Referring to communication dataTroubleshooting Memo Confirmation details Check Items to confirm before starting up CC-Link systemRUN Errl SD RD Meanings of LEDs on CC-Link compatible moduleConfirmation item TroubleshootingProgramming unit error display confirmation CC-Link compatible module LED confirmation Confirmation from master station PLC Emg.stop on Error messages relating to CC-LinkMemo Specifications Memo Profile Remote registers Device No Signal name Details RXn0 Details of remote input/output signalsDetails of remote input/output signals Details of remote input/output signals Initial data process for CC-Link connection Dedicated input/output signal timing chartServo on and emergency stop Initial servo on process after power onShift to emergency stop Servo on process from emergency stop statusAuto mode changeover process SpecificationsProgram reset process Program execution processStopping with program interlock Program stop process using interlock inputDetails of sample Sample programRobot program data assignment Variables used Points usedBit information used X1FF PLC data assignmentGosub *PLACE Robot program 1st unit’s RCX40 2nd unit’s RCX142X0F From PLC programRET From H0 Set initial data process complete flag OFF Communication speed setting CC-Link compatible module specificationsMemo Appendix Memo Term definition Unit