2
Connection
6.Parameter setting for
6.1Parameter setting for CC-Link serial I/O board
1) | Press the | F 1 | (PARAM) key in “SYSTEM” mode to enter “SYSTEM>PARAM” |
| mode. |
|
|
2) | Press the | F 5 | (OP. BRD) key in “SYSTEM>PARAM” mode to enter the option |
board parameter setting mode.
The option boards installed in the controller are displayed in order on the MPB screen.
Fig.
SYSTEM>PARAM>OP.BRDV8.18
1.DIO_N(1) |
| VALID |
|
|
|
2.
3.CCLnk(S1/10M)VALID
4.
SELECT
Option boards installed into the option slots are displayed on the MPB screen.
Type | Display | Meaning | |
|
|
| |
| DIO_N(n) | An option DIO board of NPN specifications is installed. The | |
| number in parentheses is an ID number. | ||
|
| ||
Option DIO |
|
| |
DIO_P(n) | An option DIO board of PNP specifications is installed. The | ||
| |||
| number in parentheses is an ID number. | ||
|
| ||
|
|
| |
| CCLnk(n/m) | A | |
| number "n" and a communication speed "m". | ||
|
| ||
|
|
| |
Serial I/O | D_Net(n/m) | A DeviceNet unit is installed. Letters in parentheses indicate a | |
MAC ID number "n" and communication speed "m". | |||
|
| ||
|
|
| |
| Profi(n/m) | A ProfiBUS unit is installed. Letters in parentheses indicate a | |
| Station address "n" and communication speed "m". | ||
|
| ||
|
|
| |
Network | E_Net | An Ethernet unit is installed. | |
|
|
|
3) In “SYSTEM>PARAM>OP. BRD” mode, select the “CCLnk” with the cursor (↑/↓) keys and press the F 1 (SELECT) key.
Fig.
SYSTEM>PARAM>OP.BRD>SELECT V8.18
| 1.board condition |
| VALID |
| ||||||||
| 2.remote cmd / IO cmd(SI05) |
| VALID | |||||||||
| 3.Output MSG to SOW(1) |
| INVALID | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
EDIT |
| JUMP |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|