Siemens DTU3005-B manual Installing the Software

Page 10

2 Installing the Software

2 Installing the Software

The DTU3005 Editor software can be installed from the DOS prompt onto a PC running Microsoft® Win- dows version 3.1, 95, or 98. The PC processor must be less than 300 MHz (or have a utility program installed to slow down the processor speed) for the Editor soft- ware to work properly.

Note: The DTU3005 Editor software does not work in a Windows NT environment.

If you are running Windows 3.1, double click the MS- DOS Prompt icon in the Main window of Program Manager. For Windows 95/98, select MS-DOS Prompt from the Start menu. To install the Editor software,

3.The program asks on which drive you want to install the Editor software. For most computers, this will be drive C. Type c and press Enter.

4.The installation program then asks to which sub- directory you want to install the DTU3005 Editor software. This is where the program and configu- ration files will be placed. The suggested direc- tory name is DTU3005B. Type the directory name at the prompt and press Enter.

5.You will now verify your drive and directory choices. The installation program repeats your entries and asks if the information is correct. Enter Y if it is correct, and N if it is incorrect or you have changed your mind. Then press Enter.

insert the installation diskette into your computer and follow the steps listed below. The computer screen, showing the computer prompts and user responses, is shown below.

1.Change the current drive at the DOS prompt to the diskette drive. Type A: (or B: if that is your 3½" diskette drive), and then press Enter.

2.At the A:\> prompt, type install, and then press Enter. The installation prompts you to select which Editor software to install, as shown in the example screen below. Type 1 and press Enter to install the SEAbus Device Editor, or type 2 and press Enter to install the VDEW Device Editor.

6.The installation program copies and unpacks the editor program files onto your hard drive and

6

Siemens Energy & Automation, Inc.

Image 10
Contents DTU3005-B Qualified Personnel Table of Contents 134 Diagnostic Data FormatWarranty 135Product Overview FeaturesIntroduction Software OverviewPLC to SEAbus PLC to SEAbus Application Supported PLC WinPMModbus Master to SEAbus Modbus Master to SEAbusConnection to Modbus Master using a Multidrop Cable Multi-Drop Modbus Master to SEAbusSEAbus Port Expander SEAbus Port Expander Siemens Energy & Automation, IncInstalling the Software Installing the SoftwareInstalling the Software Starting the Software Menu NavigationMain Menu Using the Project MenuStarting a New Project Starting the Software Starting the Software Creating Project Files-PLC to Devices Configuring the Project FileApplication Description PLC Setup-Port PLC Protocol Communications SettingsWire RS422 or RS485 Communications DTU AddressOther Configuration Information Device Setup-PortSaving Port 1 Configuration Information Response Time-OutSaving Port 3 Configuration Information Passthrough Setup-PortSaving Port 2 Configuration Information Intermessage Time-OutDevice List Setup Adding a DeviceCreating Project Files-PLC to Devices Configuring Custom Registers for a Single Device Configuring Custom Device RegistersSaving the Device List Configuration Removing a DeviceCreating Project Files-PLC to Devices Configuring Default Custom Device Registers by Device Creating Project Files-PLC to Devices Device Text Setup 7SJ600 Only Description of Returned Trip Global Command Registers Device Diagnostic RegistersDevice Command Registers Saving the Project File Creating Project Files-Modbus Master to Devices Creating Project Files-Modbus Master to DevicesConfiguring the Project File Modbus Setup-Port RS-485 Connector two-wire Device Setup-Port Modbus/Passthrough Setup-Port Modbus MasterWith the 2-Wire RS422 or RS485 Communications Passthrough to Port 2 SEAbusDevice List Setup Creating Project Files-Modbus Master to Devices Configuring Custom Device Registers Creating Project Files-Modbus Master to Devices Configuring Default Custom Device Registers Creating Project Files-Modbus Master to Devices Device Text Setup 7SJ600 Only Value Inputs 2 Global Command Registers Device Command Registers Creating Project Files-SEAbus Port Expander Creating Project Files-SEAbus Port ExpanderMenu, and the Port 1 Passthrough configuration Communications Settings SEAbus Device Setup-Port Configuration InformationTransferring Project Files Transferring Project FilesPersonal Computer RS-232 Port Downloading Projects