7 Transferring Project Files

7 Transferring Project Files

Once you have configured and saved your project file for your particular application, you need to download it to the DTU3005 unit. First verify which COM port on your computer is used to upload and download projects to the DTU3005 unit (see Chapter 8). Then, select Transfer from the main menu and the following selections are available:

Download project to DTU3005—allows you to transfer (download) any created project file from your PC to the DTU3005.

Upload project from DTU3005—allows you to transfer (upload) the project file stored in the DTU3005 to the PC.

Verify—allows you to verify a project file within your computer against the current project file stored in the DTU3005 unit.

Check Application in DTU3005—allows you to check what type of project file is loaded (PLC to devices, Modbus Master to devices, or Passthrough) and which protocols have been loaded for each of the communication ports. It also reports the revision level of the DTU3005 unit’s firmware.

Before using the Transfer commands, you must physi- cally connect port 3 of the DTU3005B to your com- puter using a null modem cable. Also be sure that power is supplied to the DTU3005.

Siemens Energy & Automation, Inc.

49

Image 53
Contents DTU3005-B Qualified Personnel Table of Contents Warranty Diagnostic Data Format134 135Introduction FeaturesProduct Overview Software OverviewPLC to SEAbus Application Supported PLC WinPM PLC to SEAbusModbus Master to SEAbus Modbus Master to SEAbusMulti-Drop Modbus Master to SEAbus Connection to Modbus Master using a Multidrop CableSEAbus Port Expander Siemens Energy & Automation, Inc SEAbus Port ExpanderInstalling the Software Installing the SoftwareInstalling the Software Menu Navigation Starting the SoftwareStarting a New Project Using the Project MenuMain Menu Starting the Software Starting the Software Application Description Configuring the Project FileCreating Project Files-PLC to Devices PLC Setup-Port Wire RS422 or RS485 Communications Communications SettingsPLC Protocol DTU AddressSaving Port 1 Configuration Information Device Setup-PortOther Configuration Information Response Time-OutSaving Port 2 Configuration Information Passthrough Setup-PortSaving Port 3 Configuration Information Intermessage Time-OutAdding a Device Device List SetupCreating Project Files-PLC to Devices Saving the Device List Configuration Configuring Custom Device RegistersConfiguring Custom Registers for a Single Device Removing a DeviceCreating Project Files-PLC to Devices Configuring Default Custom Device Registers by Device Creating Project Files-PLC to Devices Device Text Setup 7SJ600 Only Description of Returned Trip Device Diagnostic Registers Global Command RegistersDevice Command Registers Saving the Project File Creating Project Files-Modbus Master to Devices Creating Project Files-Modbus Master to DevicesConfiguring the Project File Modbus Setup-Port RS-485 Connector two-wire Device Setup-Port Modbus Master Modbus/Passthrough Setup-PortPassthrough to Port 2 SEAbus With the 2-Wire RS422 or RS485 CommunicationsDevice List Setup Creating Project Files-Modbus Master to Devices Configuring Custom Device Registers Creating Project Files-Modbus Master to Devices Configuring Default Custom Device Registers Creating Project Files-Modbus Master to Devices Device Text Setup 7SJ600 Only Value Inputs 2 Global Command Registers Device Command Registers Creating Project Files-SEAbus Port Expander Creating Project Files-SEAbus Port ExpanderMenu, and the Port 1 Passthrough configuration Communications Settings Configuration Information SEAbus Device Setup-PortTransferring Project Files Transferring Project FilesDownloading Projects Personal Computer RS-232 Port