Siemens DTU3005-B manual Qualified Personnel

Page 2

DANGER

Hazardous voltages and high-speed moving parts in electrical devices communicating with WinPM.

Can cause death, serious injury or property damage.

See safety instruction contained herein. Restrict use to qualified personnel.

The use of unauthorized parts in the repair of the equipment or tampering by unqualified personnel will result in dangerous conditions that can cause death, serious injury or property damage.

IMPORTANT

The information contained herein is general in nature and not intended for specific application purposes. It does not relieve the user of responsibility to use sound practices in appli- cation, installation, operation, and maintenence of the equipment purchased. Siemens reserves the right to make changes at any time without notice or obligations. Should a conflict arise between the general information contained in this publication and the contents of drawings or supple- mentary material or both, the latter shall take precedence.

QUALIFIED PERSONNEL

For the purposes of this manual and product labels, "qualified personnel" is one who is familiar with the installation, construction, or operation of the equipment and the hazards involved. In addition, s/he has the following qualifications:

(a)is trained and authorized to energize, de-energize, clear, ground, and tag circuits and equipment in accordance with established safety practices.

(b)is trained in the proper care and use of protective gear equipment such as rubber gloves, hard hat, safety glasses or face shields, flash clothing, etc., in accordance with established safety procedures

(c)is trained in rendering first aid.

SUMMARY

These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation, or maintenence. Should further infor- mation be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the local Siemens Energy & Automation, Inc. sales office.

THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT, COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS ALL OBLIGA- TIONS OF SIEMENS ENERGY & AUTOMATION, INC. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS ENERGY & AUTOMATION, INC.

ACCESS, ISGS, Isolated Multi-Drop, S7-I/O, SBwin, SAMMS-LV, SAAMS-MV,SEAbus,SIEServe, Static Trip III, Wisdom, and WinPM are trademark, Sensitrip and Sentron are registered trademarks of Siemens Energy & Automation, Inc. SIEMENS is a registered trademark and Windows is a trademark of Microsoft Corporation. All other product names mentioned herein are used for identification purposes only and may be the trademarks or registered trademarks of their respective companies.

Image 2
Contents DTU3005-B Qualified Personnel Table of Contents 134 Diagnostic Data FormatWarranty 135Product Overview FeaturesIntroduction Software OverviewPLC to SEAbus PLC to SEAbus Application Supported PLC WinPMModbus Master to SEAbus Modbus Master to SEAbusConnection to Modbus Master using a Multidrop Cable Multi-Drop Modbus Master to SEAbusSEAbus Port Expander SEAbus Port Expander Siemens Energy & Automation, IncInstalling the Software Installing the SoftwareInstalling the Software Starting the Software Menu NavigationStarting a New Project Using the Project MenuMain Menu Starting the Software Starting the Software Application Description Configuring the Project FileCreating Project Files-PLC to Devices PLC Setup-Port PLC Protocol Communications SettingsWire RS422 or RS485 Communications DTU AddressOther Configuration Information Device Setup-PortSaving Port 1 Configuration Information Response Time-OutSaving Port 3 Configuration Information Passthrough Setup-PortSaving Port 2 Configuration Information Intermessage Time-OutDevice List Setup Adding a DeviceCreating Project Files-PLC to Devices Configuring Custom Registers for a Single Device Configuring Custom Device RegistersSaving the Device List Configuration Removing a DeviceCreating Project Files-PLC to Devices Configuring Default Custom Device Registers by Device Creating Project Files-PLC to Devices Device Text Setup 7SJ600 Only Description of Returned Trip Global Command Registers Device Diagnostic RegistersDevice Command Registers Saving the Project File Creating Project Files-Modbus Master to Devices Creating Project Files-Modbus Master to DevicesConfiguring the Project File Modbus Setup-Port RS-485 Connector two-wire Device Setup-Port Modbus/Passthrough Setup-Port Modbus MasterWith the 2-Wire RS422 or RS485 Communications Passthrough to Port 2 SEAbusDevice List Setup Creating Project Files-Modbus Master to Devices Configuring Custom Device Registers Creating Project Files-Modbus Master to Devices Configuring Default Custom Device Registers Creating Project Files-Modbus Master to Devices Device Text Setup 7SJ600 Only Value Inputs 2 Global Command Registers Device Command Registers Creating Project Files-SEAbus Port Expander Creating Project Files-SEAbus Port ExpanderMenu, and the Port 1 Passthrough configuration Communications Settings SEAbus Device Setup-Port Configuration InformationTransferring Project Files Transferring Project FilesPersonal Computer RS-232 Port Downloading Projects