5 Creating Project Files—Modbus Master to Devices

5Creating Project Files—Modbus Master to Devices

This chapter covers configuration of the DTU3005 for Modbus master device communications with Siemens devices. Once you have created a Modbus Master to Devices project (see Chapter 3), follow the directions in this chapter to configure the project file. Then see Chapter 7 for directions on downloading the project to the DTU3005.

5.1Application Description

The Modbus Master to Devices application allows a Modbus master (usually a SCADA system) to control

and monitor up to 32 SEAbus devices or Siemens pro- tective relays. In this application, the DTU3005B acts as a slave, and all communications with the Modbus Master are initiated by the master device itself. The DTU3005B converts Modbus requests received into requests to access and control data on the Siemens devices. Registers are assigned for each device in the Holding Register range (40000 to 49999, where regis- ter 40001 is the first to be used). The Modbus Master accesses real-time data from the Siemens devices by reading these registers, and sends commands by writ- ing to these registers. Refer to Figure 5.1 for a matrix representation of these registers.

Figure 5.1 Modbus Master to Devices Project—Data Registers Matrix

28

Siemens Energy & Automation, Inc.

Image 32
Contents DTU3005-B Qualified Personnel Table of Contents Diagnostic Data Format Warranty134 135Features IntroductionProduct Overview Software OverviewPLC to SEAbus PLC to SEAbus Application Supported PLC WinPMModbus Master to SEAbus Modbus Master to SEAbusConnection to Modbus Master using a Multidrop Cable Multi-Drop Modbus Master to SEAbusSEAbus Port Expander SEAbus Port Expander Siemens Energy & Automation, IncInstalling the Software Installing the SoftwareInstalling the Software Starting the Software Menu NavigationStarting a New Project Using the Project MenuMain Menu Starting the Software Starting the Software Application Description Configuring the Project FileCreating Project Files-PLC to Devices PLC Setup-Port Communications Settings Wire RS422 or RS485 CommunicationsPLC Protocol DTU AddressDevice Setup-Port Saving Port 1 Configuration InformationOther Configuration Information Response Time-OutPassthrough Setup-Port Saving Port 2 Configuration InformationSaving Port 3 Configuration Information Intermessage Time-OutDevice List Setup Adding a DeviceCreating Project Files-PLC to Devices Configuring Custom Device Registers Saving the Device List ConfigurationConfiguring Custom Registers for a Single Device Removing a DeviceCreating Project Files-PLC to Devices Configuring Default Custom Device Registers by Device Creating Project Files-PLC to Devices Device Text Setup 7SJ600 Only Description of Returned Trip Global Command Registers Device Diagnostic RegistersDevice Command Registers Saving the Project File Creating Project Files-Modbus Master to Devices Creating Project Files-Modbus Master to DevicesConfiguring the Project File Modbus Setup-Port RS-485 Connector two-wire Device Setup-Port Modbus/Passthrough Setup-Port Modbus MasterWith the 2-Wire RS422 or RS485 Communications Passthrough to Port 2 SEAbusDevice List Setup Creating Project Files-Modbus Master to Devices Configuring Custom Device Registers Creating Project Files-Modbus Master to Devices Configuring Default Custom Device Registers Creating Project Files-Modbus Master to Devices Device Text Setup 7SJ600 Only Value Inputs 2 Global Command Registers Device Command Registers Creating Project Files-SEAbus Port Expander Creating Project Files-SEAbus Port ExpanderMenu, and the Port 1 Passthrough configuration Communications Settings SEAbus Device Setup-Port Configuration InformationTransferring Project Files Transferring Project FilesPersonal Computer RS-232 Port Downloading Projects