Siemens DTU3005-B manual Device Text Setup 7SJ600 Only

Page 27

4 Creating Project Files—PLC to Devices

To conserve registers when using VDEW devices, you should set all unused registers to “Not Used” and place them at the end of the list. The DTU3005 will then only allo- cate registers for those containing device data. (This does not apply to SEAbus devices, for which the DTU3005 allo- cates 16 registers regardless if they are used or not.)

4.8Device Text Setup (7SJ600 Only)

The Device Text to Values Table menu item is only available for configuring the 7SJ600 relay. It is used to convert status

Once open, 64 conversions can be defined. To define a conversion, enter the 7SJ600 relay status code in the Text # column and enter the corresponding output value desired in the Value column.

codes returned from select parameters in the 7SJ600 relay (only) to values in a format useful to the system connected to port 2 of the DTU3005. This affects the status readouts from the device's binary inputs, signal and trip rated con- tacts, and the LEDs.

To edit this table, select Device Text to Values Table from the Edit menu. This selection is only available when the device protocol for port 2 is set for “VDEW.”

Siemens Energy & Automation, Inc.

23

Image 27
Contents DTU3005-B Qualified Personnel Table of Contents 135 Diagnostic Data FormatWarranty 134Software Overview FeaturesIntroduction Product OverviewPLC to SEAbus Application Supported PLC WinPM PLC to SEAbusModbus Master to SEAbus Modbus Master to SEAbusMulti-Drop Modbus Master to SEAbus Connection to Modbus Master using a Multidrop CableSEAbus Port Expander Siemens Energy & Automation, Inc SEAbus Port ExpanderInstalling the Software Installing the SoftwareInstalling the Software Menu Navigation Starting the SoftwareUsing the Project Menu Main MenuStarting a New Project Starting the Software Starting the Software Configuring the Project File Creating Project Files-PLC to DevicesApplication Description PLC Setup-Port DTU Address Communications SettingsWire RS422 or RS485 Communications PLC ProtocolResponse Time-Out Device Setup-PortSaving Port 1 Configuration Information Other Configuration InformationIntermessage Time-Out Passthrough Setup-PortSaving Port 2 Configuration Information Saving Port 3 Configuration InformationAdding a Device Device List SetupCreating Project Files-PLC to Devices Removing a Device Configuring Custom Device RegistersSaving the Device List Configuration Configuring Custom Registers for a Single Device Creating Project Files-PLC to Devices Configuring Default Custom Device Registers by Device Creating Project Files-PLC to Devices Device Text Setup 7SJ600 Only Description of Returned Trip Device Diagnostic Registers Global Command RegistersDevice Command Registers Saving the Project File Creating Project Files-Modbus Master to Devices Creating Project Files-Modbus Master to DevicesConfiguring the Project File Modbus Setup-Port RS-485 Connector two-wire Device Setup-Port Modbus Master Modbus/Passthrough Setup-PortPassthrough to Port 2 SEAbus With the 2-Wire RS422 or RS485 CommunicationsDevice List Setup Creating Project Files-Modbus Master to Devices Configuring Custom Device Registers Creating Project Files-Modbus Master to Devices Configuring Default Custom Device Registers Creating Project Files-Modbus Master to Devices Device Text Setup 7SJ600 Only Value Inputs 2 Global Command Registers Device Command Registers Creating Project Files-SEAbus Port Expander Creating Project Files-SEAbus Port ExpanderMenu, and the Port 1 Passthrough configuration Communications Settings Configuration Information SEAbus Device Setup-PortTransferring Project Files Transferring Project FilesDownloading Projects Personal Computer RS-232 Port