1 Introduction

1 Introduction

1.1Product Overview

The Panel-Tec DTU3005 is an intelligent, multiple- function data transfer unit that enables communica- tions between Siemens communicating power meters, trip units, and protective relays, and PLCs or Modbus networks. The device is designed for the harsh industrial environment and is suited for use in switchgear. The device is shown below in Figure 1.1. The device is powered from an external power supply. Three ports allow for connection to the Siemens ACCESS devices and selected protective relays, a PLC or a Modbus RTU or ASCII master system, and a passthrough, which allows direct communications with port 1 or port 2 from port 3. Status lights indicate proper operation, and DIP switches allow access to programming and diagnostic modes.

The DTU3005 device supports a wide variety of PLCs and Siemens ACCESS devices. Appendix A lists the PLCs and protocols supported by the DTU3005. Appendix B lists the supported Siemens ACCESS devices and protective relays.

Figure 1.1 Panel-Tec DTU3005 View Showing 3 Ports and Power Supply

1.2Software Overview

The DTU3005 Editor software is a MS-DOS based pro- gram for configuring the DTU3005 device. It provides for uploading and downloading configurations via the computer’s serial port. You can edit and save configu- rations in project files on your computer’s hard drive. Chapters 2 through 8 discuss installing and using the editor software to configure your DTU3005 device.

1.3Features

Device Features:

Compact size (8" x 6" x 1")

Port 1 and Port 3 Features

Transfer data directly to one of 25 PLCs sup- ported

Baud rates up to 187,500

Addressable Modbus RTU slave capability

(Port 3) Passthrough Port for connection to WinPM

Port 2 Features

Twelve Siemens ACCESS devices supported

Ten Siemens protective relays supported

Editor Software Features:

MS-DOS based (also runs under Microsoft Win- dows)

Menu driven

Mouse supported (but not required)

1.4Applications

The following are possible hardware configurations using the DTU3005 to connect to Siemens ACCESS devices.

Siemens Energy & Automation, Inc.

1

Image 5
Contents DTU3005-B Qualified Personnel Table of Contents Warranty Diagnostic Data Format134 135Introduction FeaturesProduct Overview Software OverviewPLC to SEAbus Application Supported PLC WinPM PLC to SEAbusModbus Master to SEAbus Modbus Master to SEAbusMulti-Drop Modbus Master to SEAbus Connection to Modbus Master using a Multidrop CableSEAbus Port Expander Siemens Energy & Automation, Inc SEAbus Port ExpanderInstalling the Software Installing the SoftwareInstalling the Software Menu Navigation Starting the SoftwareStarting a New Project Using the Project MenuMain Menu Starting the Software Starting the Software Application Description Configuring the Project FileCreating Project Files-PLC to Devices PLC Setup-Port Wire RS422 or RS485 Communications Communications SettingsPLC Protocol DTU AddressSaving Port 1 Configuration Information Device Setup-PortOther Configuration Information Response Time-OutSaving Port 2 Configuration Information Passthrough Setup-PortSaving Port 3 Configuration Information Intermessage Time-OutAdding a Device Device List SetupCreating Project Files-PLC to Devices Saving the Device List Configuration Configuring Custom Device RegistersConfiguring Custom Registers for a Single Device Removing a DeviceCreating Project Files-PLC to Devices Configuring Default Custom Device Registers by Device Creating Project Files-PLC to Devices Device Text Setup 7SJ600 Only Description of Returned Trip Device Diagnostic Registers Global Command RegistersDevice Command Registers Saving the Project File Creating Project Files-Modbus Master to Devices Creating Project Files-Modbus Master to DevicesConfiguring the Project File Modbus Setup-Port RS-485 Connector two-wire Device Setup-Port Modbus Master Modbus/Passthrough Setup-PortPassthrough to Port 2 SEAbus With the 2-Wire RS422 or RS485 CommunicationsDevice List Setup Creating Project Files-Modbus Master to Devices Configuring Custom Device Registers Creating Project Files-Modbus Master to Devices Configuring Default Custom Device Registers Creating Project Files-Modbus Master to Devices Device Text Setup 7SJ600 Only Value Inputs 2 Global Command Registers Device Command Registers Creating Project Files-SEAbus Port Expander Creating Project Files-SEAbus Port ExpanderMenu, and the Port 1 Passthrough configuration Communications Settings Configuration Information SEAbus Device Setup-PortTransferring Project Files Transferring Project FilesDownloading Projects Personal Computer RS-232 Port