Siemens DTU3005-B manual PLC Setup-Port

Page 17

4 Creating Project Files—PLC to Devices

Device Command Registers—allows you to indicate which PLC registers will be used for device commands.

Device Defaults—allows you to set the default data registers for more than one device of a certain type, e.g., set the defaults for all 4720 power meters or all S7-I/O units. The data registers can still be customized for each device, as required. See Section 4.7.2 for more information.

Device List—allows you to indicate which SEAbus devices or Siemens protective relays are connected to port 2 and which PLC registers they are communicat- ing with.

If the Device Protocol for port 2 is set to VDEW (see Section 4.4), then two additional menu items are available: Global Command Registers and Device Text to Values Table. See Section 4.8 and Section 4.9 for instructions on using these menu items.

4.3PLC Setup—Port 1

You must have a PLC to Devices project file open to config- ure port 1 using the instructions in this section. Select Port 1 (PLC) from the Edit menu, and the Port 1 PLC Configura- tion screen appears.

Siemens Energy & Automation, Inc.

13

Image 17
Contents DTU3005-B Qualified Personnel Table of Contents Warranty Diagnostic Data Format134 135Introduction FeaturesProduct Overview Software OverviewPLC to SEAbus Application Supported PLC WinPM PLC to SEAbusModbus Master to SEAbus Modbus Master to SEAbusMulti-Drop Modbus Master to SEAbus Connection to Modbus Master using a Multidrop CableSEAbus Port Expander Siemens Energy & Automation, Inc SEAbus Port ExpanderInstalling the Software Installing the SoftwareInstalling the Software Menu Navigation Starting the SoftwareStarting a New Project Using the Project MenuMain Menu Starting the Software Starting the Software Application Description Configuring the Project FileCreating Project Files-PLC to Devices PLC Setup-Port Wire RS422 or RS485 Communications Communications SettingsPLC Protocol DTU AddressSaving Port 1 Configuration Information Device Setup-PortOther Configuration Information Response Time-OutSaving Port 2 Configuration Information Passthrough Setup-PortSaving Port 3 Configuration Information Intermessage Time-OutAdding a Device Device List SetupCreating Project Files-PLC to Devices Saving the Device List Configuration Configuring Custom Device RegistersConfiguring Custom Registers for a Single Device Removing a DeviceCreating Project Files-PLC to Devices Configuring Default Custom Device Registers by Device Creating Project Files-PLC to Devices Device Text Setup 7SJ600 Only Description of Returned Trip Device Diagnostic Registers Global Command RegistersDevice Command Registers Saving the Project File Creating Project Files-Modbus Master to Devices Creating Project Files-Modbus Master to DevicesConfiguring the Project File Modbus Setup-Port RS-485 Connector two-wire Device Setup-Port Modbus Master Modbus/Passthrough Setup-PortPassthrough to Port 2 SEAbus With the 2-Wire RS422 or RS485 CommunicationsDevice List Setup Creating Project Files-Modbus Master to Devices Configuring Custom Device Registers Creating Project Files-Modbus Master to Devices Configuring Default Custom Device Registers Creating Project Files-Modbus Master to Devices Device Text Setup 7SJ600 Only Value Inputs 2 Global Command Registers Device Command Registers Creating Project Files-SEAbus Port Expander Creating Project Files-SEAbus Port ExpanderMenu, and the Port 1 Passthrough configuration Communications Settings Configuration Information SEAbus Device Setup-PortTransferring Project Files Transferring Project FilesDownloading Projects Personal Computer RS-232 Port