Section 4, Network Turnup Procedure

 

 

4.CHANNEL SELECTION

The FCC has allocated 125 MHz of spectrum in the 5.8 GHz band where the TRACER 5045 operates. Figure 1 illustrates the bandwidth division.

AB

5725 MHz 5747

5827 5850 MHz

Figure 1. 5.8 GHz Bandwidth Division

To designate the utilization of the ISM bandwidth, there are two different channel plans, labeled A and B. The letter of each channel plan setting is preset by the factory and refers to the physical configuration of the diplexer filter inside the chassis. The channel plan (A or B) refers to which half of the band the radio transmits in. For example, a Plan A radio will transmit in Channel A and receive in Channel B. A Plan B radio will transmit in channel B and receive in Channel A. The transmitter at one end of the link must transmit in the lower portion of the spectrum and receive in the upper portion. Consequently, the receiver at the other end must receive in the lower portion and transmit in the upper portion.

The letter of the channel plan (A or B) must be different on both ends. Shipment of a link will consist of one Plan A and Plan B unit. The channel plan of the unit may be changed in the field, if necessary, by rewiring the internal diplexer. Contact ADTRAN Technical Support for more information on this procedure.

5.GROUNDING INSTRUCTIONS

The following provides grounding instruction information from the Underwriters’ Laboratory UL 60950 Standard for Safety of Information Technology Equipment Including Electrical Business Equipment, of December, 2000.

An equipment grounding conductor that is not smaller in size than the ungrounded branch-circuit supply conductors is to be installed as part of the circuit that supplies the product or system. Bare, covered, or insulated grounding conductors are acceptable. Individually covered or insulated equipment grounding conductors shall have a continuous outer finish that is either green, or green with one or more yellow stripes. The equipment grounding conductor is to be connected to ground at the service equipment.

The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding type, and the equipment grounding conductors serving these receptacles are to be connected to earth ground at the service equipment.

A supplementary equipment grounding conductor shall be installed between the product or system and ground that is in addition to the equipment grounding conductor in the power supply cord.

612805045L1-1A

© 2003 ADTRAN, Inc.

37

Image 37
Contents Tracer To the Holder of the Manual TrademarksAbout this Manual Revision History Save These Important Safety Instructions Safety InstructionsRadio Frequency Interface Statement FCC-Required InformationExposure to Radio Frequency Fields FCC Output Power RestrictionsPre-Sales Inquiries and Applications Support Repair and ReturnPost-Sale Support Installation and Maintenance SupportTraining Table of Contents Table of Contents Tracer 4208 System Manual System Description Configuration and Management Features and BenefitsSystem Overview OperationalLine-of-Site Receiver PowerReceiver Sensitivity Antenna Information Other ConsiderationsMicrowave Path Engineering Basics Tracer 5045 System Manual Terminology LINE-OF-SITEDecibels Calculating the Fade MarginReceiver Power Antenna Gain Transmitted Power PTPath Distance d Carrier Wavelength λSystem Losses L Typical Coaxial Loss for Common Cable Types Path Loss LPAntenna Information Receiver SensitivityAntenna Alignment Path Loss for Given Path Lengths MilesAntenna Beam Patterns Tracer Rssi Test PointsFresnel Zones, Earth Curvature, & Antenna Heights Minimum Antenna Height for Given Path Lengths Path Availability Other ConsiderationsTerrain Terrain Factor Description Climate Climate Factor DescriptionMicrowave Path Engineering Basics Tracer 5045 System Manual Reviewing the Front Panel Design At-A-Glance SpecificationsPower Requirements Equipment DimensionsReviewing the Front Panel Design Rssi Monitoring InterfaceReviewing the Tracer 5045 Rear Panel Design RS-232 Connection DB-25 Terminal Use Rear Panel Description Name ConnectorRS-232 Connection Pinout RS-232 Connection Modem Use Tracer 5045 DCE to Terminal DTE Diagram DB-25Tracer 5045 DCE to Personal Computer DB-9 10/100BaseT/TX Connections RJ-48C Alarm Contacts Plug-In Terminal BlockTracer 5045 DCE to Modem DCE DB-25 100BaseT/Tx Interface PinoutAntenna Interface N-Type connector DC Power Connection Plug-In Terminal BlockAT-A-GLANCE Specifications FuseHardware Description Specification Transmitter Hardware Description Specification Power Engineering Guidelines Tracer 5045 System Manual Unpack and Inspect the System Network Turnup ProcedureIntroduction Contents of Adtran ShipmentTools Required Unpack and Inspect the SystemGrounding Instructions Channel SelectionConnecting the Ethernet Interfaces Supplying Power to the UnitMounting Options Terminal Menu and System Control Navigating the Terminal MenuMenu Descriptions Terminal Menu Window Navigating the Terminal MenuPassword Protection Navigating using the Keyboard KeysTerminal Menu and System Control To do this Press this keyContact Information Menu DescriptionsTx Power Rx PowerRF Status Ethernet StatusMain Menu Tracer System Configuration Default password for the Tracer 5045 is tracer Tracer Link Performance History Ethernet Switch Status Ethernet Switch Status RX Packets Dropped User Interface Guide Tracer 5045 System Manual Overview Installing/Troubleshooting the Tracer HardwareOverview LED Indicators PWR LEDTST LED RF Down LEDSTEP-BY-STEP Troubleshooting RF ErrorsRF LOW LED LAN LEDsINSTALLING/TROUBLESHOOTING the Tracer Hardware Installing/Configuring Ethernet Hardware Troubleshooting Guide Tracer 5045 System Manual