ADTRAN 5045 RF Status, Ethernet Status, Remote Tracer Status, Local Tracer Status, Frequency Plan

Page 43

TRACER 5045 System Manual

Section 5 User Interface Guide

 

 

C. RF Status

A graphical indicator of the TRACER RF links is located beneath the Technical Support contact number. The status of the received radio link is indicated as RF UP or RF DOWN for each direction. This RF status display corresponds to the RF DOWN LED on the front of the unit.

D. Ethernet Status

A visual status of the current configuration for each 10/100BaseT/TX ethernet interface (for both the local and remote TRACER systems) is provided on the TRACER 5045 System Status menu page. The current operational speed of each ethernet interface (10BT or 100BT) indicates whether the interface is 10BaseT or 100BaseTX. A blank line next to the port number indicates there is no active ethernet link on the interface. A separate ethernet status page is accessible from the main menu to provide detailed ethernet information.

E. Remote TRACER Status

The right portion of the TRACER 5045 System Status menu page reports the status of the remote TRACER 5045 (the system across the wireless link from the active terminal). If the RF link is down, DATA NOT AVAILABLE is displayed in place of the remote system status information.

F. Local TRACER Status

The left portion of the TRACER 5045 System Status menu page reports the status of the local TRACER 5045 (the system where the active terminal is attached).

G. Frequency Plan

Displays the frequency plan (A or B) for the TRACER 5045 unit. For an operational TRACER 5045 system you should have one A and one B frequency plan.

H. Rx Quality

Displays an indicator of receive signal quality that is not necessarily related to receive signal level (for both the local and remote units) using a series of symbols (#). The more symbols displayed, the better the signal quality. This indicator is related to signal-to-noise ratio and features a colon (:) marker to indicate 10-6bit error rate. This indicator is useful as a diagnostic tool to help identify interference, as the system may have high receive signal level and poor signal quality in situations where interference is an issue.

I. Rx Power

Displays the approximate receiver levels (for both the local and remote units) using a series of symbols (#). The more symbols (#) displayed, the stronger the signal. If the link is down and remote end data is unavailable, DATA NOT AVAILABLE is displayed in place of the symbols (#).

J. Tx Power

Displays the approximate transmitter levels (for both the local and remote units) using a series of symbols (#). The more symbols (#) displayed, the stronger the signal. If the link is down and remote end data is unavailable, DATA NOT AVAILABLE is displayed in place of the symbols (#).

K. Navigation Reminders

Displays system navigation reminders. For more details on system navigation, refer to Navigating the Terminal Menu on page 40.

612805045L1-1A

© 2003 ADTRAN, Inc.

43

Image 43
Contents Tracer To the Holder of the Manual TrademarksAbout this Manual Revision History Save These Important Safety Instructions Safety InstructionsRadio Frequency Interface Statement FCC-Required InformationExposure to Radio Frequency Fields FCC Output Power RestrictionsPre-Sales Inquiries and Applications Support Repair and ReturnPost-Sale Support Installation and Maintenance SupportTraining Table of Contents Table of Contents Tracer 4208 System Manual System Description Operational Features and BenefitsConfiguration and Management System OverviewOther Considerations Receiver PowerLine-of-Site Receiver Sensitivity Antenna InformationMicrowave Path Engineering Basics Tracer 5045 System Manual Calculating the Fade Margin LINE-OF-SITETerminology DecibelsReceiver Power Antenna Gain Transmitted Power PTPath Distance d Carrier Wavelength λSystem Losses L Typical Coaxial Loss for Common Cable Types Path Loss LPPath Loss for Given Path Lengths Miles Receiver SensitivityAntenna Information Antenna AlignmentAntenna Beam Patterns Tracer Rssi Test PointsFresnel Zones, Earth Curvature, & Antenna Heights Minimum Antenna Height for Given Path Lengths Climate Climate Factor Description Other ConsiderationsPath Availability Terrain Terrain Factor DescriptionMicrowave Path Engineering Basics Tracer 5045 System Manual Reviewing the Front Panel Design At-A-Glance SpecificationsRssi Monitoring Interface Equipment DimensionsPower Requirements Reviewing the Front Panel DesignReviewing the Tracer 5045 Rear Panel Design RS-232 Connection DB-25 Terminal Use Rear Panel Description Name ConnectorRS-232 Connection Pinout RS-232 Connection Modem Use Tracer 5045 DCE to Terminal DTE Diagram DB-25Tracer 5045 DCE to Personal Computer DB-9 100BaseT/Tx Interface Pinout Alarm Contacts Plug-In Terminal Block10/100BaseT/TX Connections RJ-48C Tracer 5045 DCE to Modem DCE DB-25Fuse DC Power Connection Plug-In Terminal BlockAntenna Interface N-Type connector AT-A-GLANCE SpecificationsHardware Description Specification Transmitter Hardware Description Specification Power Engineering Guidelines Tracer 5045 System Manual Unpack and Inspect the System Network Turnup ProcedureUnpack and Inspect the System Contents of Adtran ShipmentIntroduction Tools RequiredGrounding Instructions Channel SelectionConnecting the Ethernet Interfaces Supplying Power to the UnitMounting Options Terminal Menu and System Control Navigating the Terminal MenuMenu Descriptions Terminal Menu Window Navigating the Terminal MenuTo do this Press this key Navigating using the Keyboard KeysPassword Protection Terminal Menu and System ControlContact Information Menu DescriptionsEthernet Status Rx PowerTx Power RF StatusMain Menu Tracer System Configuration Default password for the Tracer 5045 is tracer Tracer Link Performance History Ethernet Switch Status Ethernet Switch Status RX Packets Dropped User Interface Guide Tracer 5045 System Manual Overview Installing/Troubleshooting the Tracer HardwareRF Down LED LED Indicators PWR LEDOverview TST LEDLAN LEDs RF ErrorsSTEP-BY-STEP Troubleshooting RF LOW LEDINSTALLING/TROUBLESHOOTING the Tracer Hardware Installing/Configuring Ethernet Hardware Troubleshooting Guide Tracer 5045 System Manual