Canon Model 6401 B manual Baud, S300, Free, Quit, Transfer

Page 44

Field Test Unit Software

7.8.2 “F” - FREE

This command will display all files held in RAM and available memory. (See X-07 manual for more details).

7.8.3 “Q” - QUIT

Pressing this key will return the X-07 to BASIC.

7.8.4 “b” - BAUD

This command will allow the user to set the FTU’s communication baud rate. The default is 8000 baud. Users of remote telemetry systems should consult their manual 6213 to decide on the correct baud rate if using a

MODEM.

7.8.5 “s” - S300

This command will cause the FTU-PROM to exit from normal communica- tions with the logger and to assume a “dumb terminal” mode for communica- tions with another terminal.

7.8.6 “x” - TRANSFER

This command will allow the FTU to transfer files between itself and an IBM PC compatible using UNIDATA’s PDL-FTU software version 1.5 or later. File transfer can be done in either direction. Once “x” has been pressed all commands take place from the PC. See software manual 6201 “STARLOG Software Manual” for further details.

Image 44
Contents Starlog Copyright Notice Table of Contents To CASSETTE/RAM RecordingsLOAD/PLOT Operator Responses Running PlotxDirect Commands from FTU-PROM CommandsDisplay Format ValuesField Test Unit Software Contents Memory structure Why use a FTU? InstallationSwitching on the FTU Running a ProgramAttaching the cassette REDSaving a Program Loading a ProgramGrey BlackFilename Extensions FTU Memory GuidePLOT/COPY/FTUC Loading PLOT’ in 16K RAM FTU Standard Features Running Copy Command FilesCopying Files Operator Responses Question Answer Timing considerationsRunning Load Printing & Plotting RecordingsRunning Plot AnswersFile name,type Hhmm Ddmmyy Buffer PRINT/PLOT/LOAD/COPY Examples Print Example Sample Field DescriptionsStart Question Operator ResponsePlot Example Load Example Hhmm Ddmmyy 50,14 Load Program control variables FileCopy Example InputPlotx Operator Responses QuestionMeaning= Green Sample Field DescriptionLines on the X-710 printer to produce L/F Header Message FormatHeader message Line Data Message Format Data messages Line 2 onwardsEND Message Format END messageData Storage Format Command OperationINITIALlZATlON 5 ‘space’ CommandCursor KEY Commands Next Locate 0,1PRINT USING####BL Locate 0,3PRINT? LB P Channel AddressesNFTU.X07 Program Listing CLSPRINT#1,KKKON Error Goto 0V = Clsinputloc Lgoto If M=1 then M=2 Else M=1 GotoClsinputblockbgoto Clsinputput NextDisplay of the Loggers Current Memory Values User Defined Screen Format Key Stroke FunctionExample FTU to lock up on power on Commands to Modify Data LoggerTime DisplayX-07 Direct Commands from FTU-PROM TimeBaud S300Free QuitIndirect and Miscellaneous Commands CLR Summary of CommandsHome Pdlftu ALL Recorded Data will be Lost