6. NFTU COMMANDS
The program NFTU is a simple Field Test Unit program which will com- municate with the Model 6003 Data Logger and display (or alter) the Data Logger memory contents.
This Software Package is unsupported by UNIDATA. This means that the software is supplied ‘as is’ and UNIDATA does not intend to correct any errors or make further improvements to the package.
Memory location may be displayed as groups of 4 single bytes or as a 32 bit integer number.
6.1 OPERATION
1. Turn the FTU on using the “on/break” key.
2.Plug the FTU 25 pin D type connector into the data logger computer connector.
3.The FTU will display the value of the cycle counter (location 4)
4.Press a key L, B, P, ASDF or a ‘space’ and wait for a prompt.
5.When finished, remove the FTU plug and turn the power off using the “off key.
6.1.1L COMMAND
The L command allows you to enter a number from 0 to 255 and view that byte LOCATION in the current block. The display is reset to ‘byte mode’.
6.1.2 B COMMAND
The B command allows you to enter a number from 0 to 255 and shift to that BLOCK of memory for display or alteration. The display is reset to ‘byte mode’.
28 | Section 6. NFTU COMMANDS |