Field Test Unit Software
7.7.4 “r” - RESET *
This command resets the logger data storage to an original state. All data is lost and the logger starts logging immediately.
7.7.5 “j” & “a” - JUMP TO LOG & ADDRESS toggle *
These two commands are used together to view data in the logger memory. By pressing “j” the user can access specific logs. Selection of a log number will cause the FTU to display the logged data. Use of the cursor key pad wilI enable the user to move through the logs.
By pressing “a” the user can interchange the bottom line from an address dis- play to that of the loggers time reading at each specific log. If the screen is cleared and set up prior to entering “j” then the FTU will display the logged data in actual units rather than raw bytes.
7.7.6 “D” - DATA
This command will cause the FTU to prompt “Data Buffer
7.7.7 “J” - JUMP to ADDRESS
Jump to address pointed to by the start, end or current pointer, (this infor- mation can be displayed by the above command). The user will be required to enter in the desired buffer number
7.8 X-07 DIRECT COMMANDS FROM FTU-PROM
7.8.1 “t” | - | TIME |
|
|
|
To reset the | internal clock/calendar type | “t”. The | new date if required | ||
is entered | by writing | over the old date and then | pressing | “RETURN”. |
Section 7. FTUC COMMANDS | 3 7 |