Extron electronic 124, 84, 1616, 1212, 88 Switcher Error Responses, Using the Command/Response Table

Models: 88 816 128 168 124 1212 1616 84

1 104
Download 104 pages 48.84 Kb
Page 75
Image 75
Switcher Error Responses

Switcher Error Responses

When the switcher receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the switcher is unable to perform the command because the command is invalid or contains invalid parameters, the switcher returns an error response to the host. The error response codes are:

E01 — Invalid input channel number (too large)

E10 — Invalid command

E11 — Invalid preset number

E12 — Invalid output number (too large)

E13 — Invalid value (out of range)

E14 — Illegal command for this configuration

E17 — Timeout (caused only by direct write of global presets)

E22 — Busy

E25 — Device not present

E28 — Bad filename/File not found

Using the Command/Response Table

The command/response tables begin on page 4-7. Lower case letters are acceptable in the command field except where indicated for the gain and attenuation commands. The table below shows the hexadecimal equivalent of each ASCII character used in the command/response table.

Symbols are used throughout the table to represent variables. Command and response examples are shown throughout the table.

ASCII to HEX Conversion Table