Extron electronic 168, 84, 1616, 1212 Command/Response Table for SIS Commands, Symbol Definitions

Models: 88 816 128 168 124 1212 1616 84

1 104
Download 104 pages 48.84 Kb
Page 76
Image 76
Command/Response Table for SIS Commands

Programmer’s Guide, cont’d

Command/Response Table for SIS Commands

Symbol Definitions:

= Carriage return/line feed

= Carriage return (no line feed)

= Space

Esc

X1

X2

X3

X4

X5

X6

X7

X8

= Escape key

Input and output numbers in commands may be entered as either 1-digit, 2-digit, or 3-digit numbers. All input and output numbers are reported as 2-digit numbers in the response.

= Input number

01 – 08

(CrossPoint 300 84/88/816);

 

01 – 12

(CrossPoint 300 124/128);

 

01 – 16

(CrossPoint 300 168/1616)

= Input number (for tie)

0

– maximum number of inputs (0 = disconnected)

= Output number

01 – 04

(CrossPoint 300 84/124);

 

01 – 08

(CrossPoint 300 88/128/168);

 

01 – 12

(CrossPoint 300 1212);

 

01 – 16

(CrossPoint 300 816/1616)

= Mute, Lock mode, power supply

(0 = off/mode 0/not OK, 1 = on/mode 1/OK, 2 = mode 2)

= Numeric dB value

–18 to +24 (45 steps of gain or attenuation)

= Audio gain

0

– 24 (1 dB/step) (default = 0 dB)

= Audio attenuation

1

– 18 (1 dB/step)

= Volume adjustment range

0

– 64 (1 dB/step except for 0-to-1, which is 22 dB)

 

(default = 64 [0 dB])

X9

X10

X11

= Global preset #

0

– 32 (0 = current configuration)

= Video/audio mute

0

= no mutes

2 = audio mute

 

1

= video mute

3 = video and audio mute

=Firmware version number to the second decimal place (x.xx)

X12

=Verbose firmware version-description-upload date/time.

See the Query software version (verbose) command on page 4-12.

X13

X14

X15

X16

X17

X18

X19

X20

= Name

12 characters maximum for global preset names.

 

 

 

Upper- and lower-case alphanumeric characters and

 

 

 

_ / and spaces are valid.

 

 

The following characters are invalid in the name: + ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?.

 

 

= Baud rate

9600, 19200, 38400, 115200

= Parity

Odd, even, none, mark, space (only the first letter is

 

 

 

required)

= Data bits

7, 8

= Stop bits

1, 2

= Port type

0 = RS-232, 1 = RS-422

= Voltage

Positive or negative voltage magnitude

= Temperature

Degrees Fahrenheit

4-6 CrossPoint 300 Matrix Switchers • Programmer’s Guide

Page 76
Image 76
Extron electronic 168, 84, 1616, 124 Command/Response Table for SIS Commands, Symbol Definitions, Programmer’s Guide, cont’d