Rear Panel Operations

Rear Panel Operations

The rear panel has a Reset button that initiates two levels of matrix switcher resets. Press and hold the button while the switcher is running or while you apply power to the switcher for different reset levels.

Performing a system reset from the rear panel

This function is identical to the front panel system reset (see “Performing a system reset from the front panel” on page 3-36) without requiring you to power down the switcher. This function is also identical to the Esc ZXXXPerforming a system reset from the rear panel SIS command, see chapter 4, “Programmer’s Guide”). A system reset:

Clears all ties and presets

Clears all video and audio mutes

HVA switchers — Sets all input audio levels to unity gain (+0 dB)

 

 

System reset does not replace user-installed firmware upgrades.

Perform a system reset as follows:

 

 

1.

Use an Extron Tweeker to press and hold the Reset button until the rear panel

 

Reset LED blinks three times (approximately 9 seconds) (figure 3-62).

 

Press and hold

 

 

 

 

the Reset button.

Reset LED blinks

Reset LED blinks

 

 

 

 

 

 

 

 

 

 

three times.

 

four times.

 

 

 

 

 

 

Release, then immediately

 

 

RESET

9 seconds

RESET

press and release again.

RESET

 

 

 

Figure 3-62 — System reset

 

 

2.

Release the Reset button and then immediately press and release the button.

 

The LED flashes three times. Release the Reset button. The reset does not

 

occur if the second momentary press does not occur within 1 second.