Extron electronic 128, 84, 1616, 1212, 124, 168 Example 6 Saving a preset, 33 - Clear all selections

Models: 88 816 128 168 124 1212 1616 84

1 104
Download 104 pages 48.84 Kb
Page 45
Image 45
Example 6: Saving a preset

Example 6: Saving a preset

The following steps show an example in which the current configuration is saved as a preset in a CrossPoint 300 1616. The steps show the front panel indications that result from your actions.

1.

Press and release the Esc button (figure 3-33).

Press the Esc button to clear all selections.

CONTROL

The LED blinks once.

ENTER PRESET VIEW ESC

Figure 3-33 — Clear all selections

2.

Press and hold the Preset button for approximately 2 seconds until the Preset

 

LED blinks (figure 3-34).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lit

 

 

 

 

 

Unlit

 

 

 

 

 

 

 

 

 

 

 

 

(Preset Unassigned)

 

Press and hold the Preset button until

(Preset Assigned)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the Preset LED blinks.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All input and output LEDs with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

assigned presets light.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESET

 

1

 

 

 

2

 

3

 

4

 

 

 

 

 

 

 

 

Preset 17

Preset 18

Preset 19

Preset 20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you then save the configuration to a lit preset number,

 

 

 

 

 

 

 

 

the configuration data at that preset location will be overwritten.

Figure 3-34 — Enter Save Preset mode

 

 

 

 

 

 

 

 

 

 

 

3.

Press and release the Output 1 button (figure 3-35).

 

 

 

 

 

 

 

Press and release the Output 1 button.

 

The LED blinks to indicate that this preset

 

number is selected but not saved.

CONTROL

1

2

3

4

 

ENTER PRESET VIEW

Preset 17

Preset 18

Preset 19

Preset 20

The Enter LED blinks to indicate

 

 

 

 

 

 

 

 

 

 

the need to save the preset.

 

 

 

 

 

The Preset LED continues to blink.

Figure 3-35 — Select the preset

CrossPoint 300 Matrix Switchers • Operation 3-21

Page 45
Image 45
Extron electronic 128, 84, 1616, 1212, 124 Example 6 Saving a preset, 33 - Clear all selections, 34 - Enter Save Preset mode